9400 Series Programmer's Manual
COLUMN
DIRECTION
STOP
4-22
One to four digits to define the column
location of the field on the supply. This is
the distance from the guide edge zero
point at the left edge of the supply and the
left edge of the field.
The zero point is 1.5 mm or 0.060 inches
from the left edge of the supply.
The unit of measurement is tenths of
millimeters. The range must be less than
the maximum width of the supply.
Values:
9425
0-508 (0 to 2 inches)
9445
0-1016 (0 to 4 inches)
9465
0-1016 (0 to 4 inches)
9474
0-1016 (0 to 4 inches)
One digit to define the direction of the line.
Values:
0 = Vertical
1 = Horizontal
One to four digits to define the stop
position (Row or Column, dependent on
the DIRECTION setting) for the line.
Values:
1-2032