Working with hot-plug PCI adapters

This section provides the instructions needed to replace a hot-plug PCI adapter.
Notes:
1. Installation of adapters is unsupported in slots 1 and 2.
2. Hot-plug adapters are installed in slots 3 through 10 only, counting from right to
3. Hot-plug operation requires operating system support and installation of the
Complete the following steps to replace a hot-plug PCI adapter:
1. Review the information in "Before you begin" on page 3.
2. Slide the server out of the rack.
left while facing the back of the server.
required device drivers. You can determine if an adapter that is validated by IBM
supports hot-plug operation at:
http://www.ibm.com/pc/us/compat/hotplug/index.shtml. Also, refer to the
documentation provided with the adapter for information and support.
Note:
Statement 15
CAUTION:
Make sure that the rack is secured properly to avoid tipping when the server
unit is extended.
Statement 16
CAUTION:
Some accessory or option board outputs exceed Class 2 or limited power
source limits and must be installed with appropriate interconnecting
cabling in accordance with the national electric code.
Chapter 2. Installing options
7