Martin MAC Quantum Wash User Manual page 35

Hide thumbs Also See for MAC Quantum Wash:
Table of Contents

Advertisement

Short code
Long message and explanation
LED TEMP SEN ERR
LDTC
LED board temperature sensor error.
LED TEMP SEN ERR
LDTE
LED board temperature sensor error.
MISSING MODULE ERR
MMER
Impossible to communicate with a module that should be present. Module missing or not
correctly connected.
PAN ERROR
PAER
Pan position electrical indexing system timeout.
PFC TEMP CUT OFF
PFTC
Power factor correction system temperature cutoff.
PFC TEMP SEN ERR
PFTE
Power factor correction system temperature sensor error.
PAN SENSOR ERROR
PSER
Fixture unable to retrieve reliable data from pan position sensor.
P/T SENSOR ADJUST
PTCM
Pan/tilt sensors are incorrectly adjusted.
SAFETY LOOP
SLER
Safety loop circuit activated. A temperature circuit breaker has shut down LEDs. Circuit breaker
resets automatically after temperature has returned to normal operating range.
TILT ERROR
TIER
Tilt position electrical indexing circuit timeout.
TILT SENSOR ERR
TSER
Fixture unable to retrieve reliable data from tilt position sensor.
UPL ERR LED DRV
UELD
Could not upload new LED driver firmware during a firmware upload. Error cleared when new
firmware is uploaded successfully or power is cycled off and on.
UI TEMP CUTOFF
UITC
User interface (LCD display and control panel) temperature cutoff activated.
ZOOM SENSOR ERR
ZSER
Zoom position electrical indexing system timeout.
The fixture reports a calibration error if valid calibration data is not detected in EEPROM. The fixture may be
unable to read/write calibration data to EEPROM.
Table 7: Error messages