Connect LPG Tank
1. Connect LPG hose on LPG tank and fasten it to LPG inlet.
2. Turn the LPG/NG selector switch to LPG position.
3. Turn the LGP tank valve to "ON" position - full open.
4. Check the LPG to see if it is leaking and then verify that there are no leaks.
CAUTION: Use clean, fresh, regular LPG with LPG gas pressure area as we required
• DO NOT mix oil with fuel.
• DO NOT use CNG or NG.
• Clean the area around the fuel cap.
• Connect LPG hose on LPG tank and fasten it.
• Turn the LGP tank valve to "ON" position - full open.
• Attach the hose to the LPG fitting on the reducer, and then check for leaks.
• When line starts to freeze or unit starts to run abnormally, replace LPG tank with a full
tank.
15