AC Circuit Protector

The
AC
circuit
automatically switch OFF if there is a
short circuit or a significant overload of
the generator at the 20A 120V, 30A 120V
locking plug, or 120/240V locking plug
receptacle. If a AC circuit protector
switches OFF automatically, check that
the appliance is working properly and
does not exceed the rated load capacity
of the circuit before resetting the AC
circuit protector ON.
Gas Denser Device
To develop cold start performance of LPG/NG generator unit, the air REDUCER ASSY includes
one gas denser device lever, the detailed operation of the bottom is as below.
Choose the connector according to the gas you use:
● If you use LPG, you need to put the LPG hose to the LPG inlet, make the NG inlet screw
and seal well with the nut and turn the LPG/NG selector switch to LPG position.
● If you use NG, you need to put the NG
hose to the NG inlet, make the LPG inlet
screw and seal well with the nut and turn
the LPG/NG selector switch to the NG
position.
When start the cold LPG/NG generator unit,
open the valve of LPG tank or NG source, close
the resistance air valve handle, push the gas
denser device lever lightly, and keep 1-2
seconds, then stop, and then start the engine
normally.
CAUTION: Improper treatment or use of the
generator can damage it, shorten its
life and void your warranty
● The gas denser device lever only does
work after turning on the gas source valve, if start normally, no need pull the lever,
otherwise it will cause generator unit work abnormally;
● When push the gas denser device lever, the keeping time must not over 2 seconds,
otherwise it is not good for start; No need to push the gas denser device lever at every
start, only need to use when the first start of the cold generator unit or when need to
change Gas;
● If with abnormality, please contact us;
● Prohibit adjusting the LPG gas-pressure adjusting screw and gas flow adjusting screw.