Light Path Diagnostics Table - IBM Netfinity 5100 User Reference Manual

Hide thumbs Also See for Netfinity 5100:
Table of Contents

Advertisement

Status LEDs
Lit LED on
diagnostics
panel
None
The Advanced System Management
Processor has failed.
PS1
Power supply 1 has failed.
PS2
Power supply 2 has failed.
PS3
Power supply 3 has failed.
NON
Power supply redundancy has been lost.
Note:
OVER
The system has exceeded the power
capabilities of the installed power supply.
Table 17. Light path diagnostics
148
IBM® Netfinity® 5100 User's Reference

Light path diagnostics table

The System Error LED on the operator information panel is lit when certain system
errors occur. If the System Error LED on your server is lit, use the following table to
help determine the cause of the error and the action you should take.
Cause
This LED will not be lit if your
server has only one power supply;
however, the power is not
redundant with only one power
supply installed.
PS1
PS2
PS3
NON
OVER
NMI
TEMP
FAN
MEM
CPU
PCI A
PCI B
VRM
DASD1
DASD2
Verify that the Advanced System
Management Processor LED on the system
board is on. Have the system serviced.
Replace power supply 1.
Replace power supply 2.
Replace power supply 3.
Check the PS1, PS2, and PS3 LEDs and
replace any indicated power supply.
Install an additional power supply or
remove optional devices from the
server.
Install an optional additional power supply,
or remove optional devices from the server.
Action

Advertisement