Auto Mode; Sleep Mode - Carrier 40GXC Service Manual

Hide thumbs Also See for 40GXC:
Table of Contents

Advertisement

AUTO MODE

When the Auto setting is selected, at startup the unit will run in
cooling, fan only, or heating based on the room temperature at
shown below.
°F
77
73.4
68
64.4
Fig. 25 – AUTO Mode
After startup and if the unit is running in cooling, the compressor
will be de- -energized when the room temperature is 73.4_F (23_C).
If the unit was running in heating, the compressor will be
de- -energized when the room temperature is 73.4_F (23_C).
There is a 6 minute time delay before modes are switched.

SLEEP MODE

Additional energy savings can be realized by selecting the Sleep
mode. When the sleep setting is selected, the temperature set point
is adjusted automatically as shown below:
At Startup
Cooling
T
S
Fan
Heating
A09357
15
T
+3.6°F
S
T
+1.8°F
S
Cooling
Heating
T
-1.8°F
S
T
-3.6°F
S
1 HR
2 HR
Fig. 26 – SLEEP Mode
A09258

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

38gxc40gxq38gxq

Table of Contents