Carrier 40GXQ Product Data

Carrier 40GXQ Product Data

Inverter-driven high wall duct-free split system sizes 009 to 012
Hide thumbs Also See for 40GXQ:

Advertisement

40GXQ / 38GXQ Heat Pump
Inverter---Driven High Wall Duct---Free Split System
Sizes 009 to 012
The ideal compliment to your ducted system when it is impractical
or prohibitively expensive to use ductwork.

Product Data

INDUSTRY LEADING
FEATURES / BENEFITS
AN INEXPENSIVE AND CREATIVE
SOLUTION TO DESIGN PROBLEMS.
The 38GXQ/40GXQ inverter driven duct- -free split systems are a
matched combination of an outdoor condensing unit and an indoor
fan coil unit connected only by refrigerant tubing and wires.
The fan coil is mounted on the wall, near the ceiling. This selection
of fan coils permits inexpensive and creative solutions to design
problems such as:
S
S
S
S
These compact indoor fan coil units take up very little space in the
room and do not obstruct windows. The fan coils are attractively
styled to blend with most room decors.
components incorporate innovative technology to provide reliable
cooling performance at low sound levels.
Add- -ons to current space (sun room)
Special space requirements
When adding air conditioning to spaces that are heated
by hydronic or electric heat and have no ductwork.
Historical renovations or any
preserving the look of the original structure is essential.
application where
Advanced system

Advertisement

Table of Contents
loading

Summary of Contents for Carrier 40GXQ

  • Page 1: Product Data

    FEATURES / BENEFITS AN INEXPENSIVE AND CREATIVE SOLUTION TO DESIGN PROBLEMS. The 38GXQ/40GXQ inverter driven duct- -free split systems are a matched combination of an outdoor condensing unit and an indoor fan coil unit connected only by refrigerant tubing and wires.
  • Page 2 These units are fast and easy to install ensuring minimal disruption Even Temperature – The control package, including the inverter, to customers in homes or workplace. This makes the 38/40GXQ monitors outdoor and indoor temperatures as they relate to the systems the equipment of choice for retrofit applications.
  • Page 3: Model Number Nomenclature

    MODEL NUMBER NOMENCLATURE INDOOR UNIT 1--- 01 Voltage Fan Coil Unit 1 --- 115 ---1 ---60 Nominal Capacity 009 --- 3/4 Ton Unit Type 012 --- 1 Ton GXQ --- Heat Pump OUTDOOR UNIT 1--- 01 Air ---Cooled Condenser Voltage 1--- 115 ---1 ---60 Nominal Capacity Unit Type...
  • Page 4: Indoor Units

    STANDARD FEATURES AND ACCESSORIES INDOOR UNITS Ease Of Installation Mounting Brackets Low Voltage Controls Comfort Features Microprocessor Controls Wireless Remote Control Rapid Cooling/Heating Automatic Air Sweep Cold Blow Prevention Continuous Fan * Auto Restart Feature Memory Function Auto Changeover Energy Saving Features Inverter Driven Compressor A07892 Fig.
  • Page 5 DIMENSIONS - - INDOOR A08289 Net Operating Weight Unit Size In. (mm) In. (mm) In. (mm) Lbs. (Kg) 30.3 (770) 9.8 (250) 7.84 (1.99) 18.7 (8.5) 32.7 (830) 11.2 (285) 8.9 (225) 24.2 (11) Fig. 2 – Dimensions of Indoor Unit DIMENSIONS - - OUTDOOR A08290 Net Operating Weight...
  • Page 6 CLEARANCES - - INDOOR CEILING 6" (0.15m) min. 5" 5" (0.13m) (0.13m) min. min. (1.8m) FLOOR A07891 Fig. 4 – Indoor unit clearance CLEARANCES - - OUTDOOR Air-inlet Air-outlet A07894 UNIT 12k in. (mm) 20 (508) 20 (508) 24 (610) 12 (305) 12 (305) Fig.
  • Page 7: Physical Data

    PHYSICAL DATA Outdoor Unit 38GXQ Indoor Unit 40GXQ System Voltage 115 V 115 V System Voltage 115 V Control Voltage Low Voltage Pulse DC Control Voltage Low Voltage Pulse DC Rated Cooling Capacity (Btuh) 8,600 12,000 Rated Cooling Capacity (Btuh)
  • Page 8: Application Data

    APPLICATION DATA UNIT SELECTION system will be required to run at the both the maximum and the minimum load points. When selecting a variable speed system match the system capacity If it is anticipated that the system will be required to run at the range to the anticipated load range.
  • Page 9: System Operating Conditions

    If unit is exposed to strong winds, it is Long Line Applications: recommended that a wind baffle be used. Contact your Carrier representative for drawings. Do not install the outdoor or indoor 1. A field fabricated wind baffle is recommended.
  • Page 10: Drain Connections

    CONTROL SYSTEM at this speed until the load is satisfied or a maximum of 20 minutes The 40GXQ/38GXQ unit is equipped with a microprocessor after which the compressor will shut off for 3 minutes. controls to operate the system and give optimum levels of comfort After 3 minutes the cycle repeats itself until the load is satisfied.
  • Page 11: Electrical Data

    AIR THROW DATA APPROXIMATE AIR THROW ft. (m) UNIT CAPACITY Medium High 18 (5.5) 20 (6.1) 23 (7.0) 19 (5.8) 21 (6.4) 25 (7.6) SOUND RATINGS Outdoor Units Model Number Sound Power dBA Sound Pressure dBA 38GXQ009 --- --- ---1 65 / 66 54 / 55 38GXQ012 --- --- ---1...
  • Page 12: Guide Specifications

    GUIDE SPECIFICATIONS HORIZONTAL DISCHARGE OUTDOOR UNITS Size Range: 3/4 and 1 Ton Nominal Cooling and Heating Capacity Carrier Model Number: 38GXQ PART 1 – GENERAL 1.01 System Description D. Compressor 1. Compressor shall be fully hermetic variable speed rotary A. Outdoor air-cooled split system compressor sections suitable type.
  • Page 13 Cabinet shall be fully insulated for I. Operating Characteristics: improved thermal acoustic performance. The 40GXQ system shall have a minimum listed SEER (seasonal C. Fans: energy efficiency ratio) of 16 SEER at ARI conditions, and a 1. Fan shall be tangential direct-drive blower type with air minimum HSPF of 7.7.
  • Page 14 Catalog No. 38---40GX ---1PD Copyright 2009 Carrier Corp. S 7310 W. Morris St. S Indianapolis, IN 46231 Printed in U.S.A. Edition Date: 03/09 Replaces: New Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.