Initializing The B, E, F; Modification Of B, E, F - Sony DSC-F505 Service Manual

Hide thumbs Also See for DSC-F505:
Table of Contents

Advertisement

1-2-2. Initializing the B, E, F, 7 Page Data
1. Initializing the B, E, F, 7 Page Data
Note: If the B, E, F Page data has been initialized, "Modification of B, E,
F, 7 Page Data" and following adjustments need to be performed
again.
1) Modification of B, E, F, 7 page data
2) Video system adjustments
3) Camera system adjustments
Adjusting page
F
Adjusting Address
10 to FF
Adjusting page
E
Adjusting Address
00 to FF
Adjusting page
B
Adjusting Address
00 to FF
Adjusting page
7
Adjusting Address
00 to AF
Initializing Method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 6, address: 00, and set data: 2D.
3)
Select page: 6, address: 01, set data: 2D, and press the PAUSE
button of the adjustment remote commander.
4)
Select page: 6, address: 02, and check that the data changes to
"01".
5)
Perform "Modification of B, E, F, 7 Page Data".
2. Modification of B, E, F, 7 Page Data
If the B, E, F, 7 Page data has been initialized, change the data of
the "Fixed data-2" address shown in the following tables by manual
input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note: If copy the data built in the different model, the camcorder may
not operate.
3)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
4)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of B, E, F, 7 Page data
1)
Select page: 2, address: 00, and set data: 29.
2)
Select page: 2, address: 01, and set data: 29, and press the
PAUSE button of the adjustment remote commander.
3. F Page table
Note: Fixed data-1 : Initialized data. (Refer to "1. Initializing the B, E, F ,
7 Page Data".)
Fixed data-2 : Modified data. (Refer to "2. Modification of B, E, F ,
7 Page Data".)
Initial value
Address
NTSC PAL
00 to 0F
10
11
12
13
14
1C
1C
15
94
94
16
26
26
17
EC
EC
18
13
13
19
B9
B9
1A
00
00
1B
00
00
1C
00
00
1D
00
00
1E
46
46
1F
00
00
20
20
20
21
20
20
22
23
23
23
44
44
24
0A
0A
25
00
00
26
A8
A8
27
A0
A0
28
85
85
29
5C
5C
2A
4E
4E
2B
49
49
2C
45
45
2D
2E
7A
7A
2F
77
77
30
31
32
33
34
14
14
35
78
78
36
37
38
39
3A
2F
2F
3B
37
37
3C
40
40
3D
D0
D0
3E
3F
B5
B5
40
43
43
41
03
03
5-11
Remark
Fixed data-1
(Initialized data)
Flange back adj.
Light level adj.
AGC Standard Gain and Max Gain adj.
Light level adj.
F No. standard data input
Fixed data-1
HALL adj.
Fixed data-1
(Initialized data)
HALL adj.
Fixed data-1
(Initialized data)
AWB standard data input
Fixed data-1
Auto white balance adj.
Color reproduction adj.
(without ND filter)

Advertisement

Table of Contents
loading

Table of Contents