Specifications - Extech Instruments MA220 User Manual

400a ac/dc clamp meter
Hide thumbs Also See for MA220:
Table of Contents

Advertisement

Specifications

Function
Range
DC Current
40.00 ADC
400.0 ADC
AC Current
40.00 AAC
400.0 AAC
DC Voltage
400.0mV
4.000V
40.00V
400.0V
600V
AC Voltage
400.0mV
4.000V
40.00V
400.0V
600V
Resistance
400.0
4.000k
40.00k
400.0k
4.000 M
40.00M
Capacitance
40.00nF
400.0nF
4.000µF
40.00µF
100.0µF
Frequency
5.000Hz
50.00Hz
500.0Hz
5.000KHz
50.00KHz
150.0KHz
Duty Cycle
0.5% to 99.0%
Pulse Width: 100µs-100ms, Frequency: 5Hz to 150KHz
Temperature
-50.0 to 400.0°C
400 to 1000°C
-58.0 to 400.0°F
400 to 1832°F
Accuracy (of
reading)
0-20.00 ADC
± (2.5% + 6 digits)
20.00-40.00 ADC
± (3% + 6 digits)
0-300.0 ADC
± (2.5% + 6 digits)
300.0-400.0 ADC
± (3.5% + 6 digits)
0-20.00 AAC
± (3% + 10 digits)
20.00-40.00 AAC
± (5% + 10 digits)
0-300.0 AAC
± (3% + 10 digits)
300.0-400.0 AAC
± (5% + 10 digits)
± (0.8% + 3 digits)
± (1.5% + 3 digits)
± (2.0% + 3 digits)
± (1% + 10 digits)
± (2% + 5 digits)
± (2% + 5 digits)
± (1.0% + 4 digits)
± (1.5% + 2 digits)
± (2.5% + 3 digits)
± (3.5% + 5 digits)
± (5% + 30 digits)
± (3% + 5 digits)
± (3.5% + 5 digits)
± (5% + 5 digits)
± (1.5% + 5 digits)
± (1.2% + 2 digits)
Sensitivity: 5~5KHz:
10Vrms min.
5KHz~150KHz:
40Vrms min.
± (1.2% + 2 digits)
-50.0 to -20.0°C
± 7°C
-20.0 to 400.0°C
± (3% + 5 °C)
400 to 1000°C
-58.0 to 0°F
± 14°F
0 to 400.0°F
± (2.5% + 6 digits)
400 to 1832°F
± (3% + 7°F)
3
MA220-EU-EN V1.5 7/09

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MA220 and is the answer not in the manual?

Subscribe to Our Youtube Channel

Table of Contents