1-1-2.

Preparations

Note 1: For details of how remove the cabinet and boards, refer to "2.
DISASSEMBLY".
Note 2: When performing only the adjustments, the lens block and boards
need not be disassembled.
1)
Connect the equipment for adjustments according to Fig. 5-1-3.
Note 3: As removing the cabinet (L) (removing CN1051 of the control
switch block (FK-4950)) means removing the lithium 3V power
supply (BT1050), data such as date, time, user-set menus will be
lost. After completing adjustments, reset these data. If the cabinet
(L) has been removed, the self-diagnosis data, data on history of
use (total drum rotation time etc.) will be lost. Before removing,
note down the self-diagnosis data and the data on history use (data
of page: 2, address: A2 to AA). (Refer to "SELF-DIAGNOSIS
FUNCTION" for the self-diagnosis data, and to "5-4.Service
Mode" for the data on the history use.)
Note 4: Setting the "Forced Camera Power ON" Mode
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 01, and press the PAUSE
button of the adjustment remote commander.
The above procedure will enable the camera power to be turned
on with the cabinet (L) removed (with the control switch block
(FK-4950) removed). After completing adjustments, be sure to
exit the "Forced Camera Power ON Mode".
Note 5: Exiting the "Forced Camera Power ON" Mode
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 00, and press the PAUSE
button of the adjustment remote commander.
3) Select page: 0, address: 01, and set data: 00.
Pattern box
Front of the lens
5-5
1.5 m
Fig. 5-1-2