5. Switch check (2)

Page 2
Address 60 to 67
Using method:
1) Select page:2, address: 60 to 67.
2) By discriminating the display data, the pressed key can be
discriminated.
Address
00 (00 to 0A)
60
STOP
(KEY AD0)
(FK-4950 block)
(IC2204 od)
(S1009)
61
EXECUTE
(KEY AD1)
(FK-4950 block)
(IC2204 of)
(S1050)
62
PAUSE
(KEY AD2)
(FK-4950 block)
(IC2204 og)
(S1001)
PHOTO
63
(PHOTO REC)
(KEY AD3)
(FK-4950 block)
(IC2204 oh)
(S1055)
64
END SEARCH
(KEY AD4)
(ME-4950 block)
(IC2204 oj)
(S1102)
65
MEMORY+
(KEY AD5)
(ME-4950 block)
(IC2204 ok)
(S1111)
66
PANEL REVERSE
(KEY AD6)
(FP-129 board)
(IC2204 ol)
(S001)
67
PANEL OPEN
(KEY AD7)
(FP-129 board)
(IC2204 <z// )
(S002)

6. Record of Use check

Page 2
Address A2 to AA
Address
A2
A3
Drum rotation counted time (BCD code)
A4
A5
A6
User initial power on date (BCD code)
A7
A8
Final condensation occurrence date
A9
(BCD code)
AA
Using method:
1) The record of use data is displayed at page: 2, addresses: A2 to AA.
Note: This data will be erased (reset) when the cabinet (L) assy (Control switch block (FK-4950)) is removed.
19 (0B to 24)
32 (25 to 44)
REW
PLAY
(FK-4950 block)
(FK-4950 block)
(S1010)
(S1011)
EXPOSURE
FADER
(FK-4950 block)
(FK-4950 block)
(S1002)
(S1003)
LASER LINK
(FK-4950 block)
(S1006)
DISPLAY
MENU
(ME-4950 block)
(ME-4950 block)
(S1110)
(S1107)
MEMORY–
MEMORY INDEX
(ME-4950 block)
(FK-4950 block)
(S1112)
(S1105)
Function
Minutes
Hour (L)
Hour (H)
Year
Month
Day
Year
Month
Day
Data
59 (45 to 6E)
85 (6F to 9F)
FF
REC
(FK-4950 block)
(FK-4950 block)
(S1012)
(S1013, 1014)
START/STOP MODE
5SEC REC
(FK-4950 block)
(S1051)
BACK LIGHT
SELF TIMER
(FK-4950 block)
(FK-4950 block)
(S1004)
(S1005)
+SLOW
FOCUS
SHUTTER
(INFINITY)
(FK-4950 block)
(FK-4950 block)
(S1056)
(S1058)
TITLE
VOLUME+
(ME-4950 block)
(ME-4950 block)
(S1108)
(S1103)
MEMORY DELETE
MEMROY PLAY
(ME-4950 block)
(ME-4950 block)
(S1109)
(S1101)
10th place digit and 1st place digit of counted time (decimal digit)
1000th place digit and 100th place digit of counted time (decimal digit)
After setting the clock, set the date of power on next.
5-64E
B8 (A0 to D4)
EE (D5 to FF)
No key input
START/STOP MODE
START/STOP MODE
PUSH REC
NORMAL
(FK-4950 block)
(FK-4950 block)
(S1051)
(S1051)
No key input
FOCUS
(AUTO/MANUAL)
No key input
(FK-4950 block)
(S1057)
VOLUME–
(ME-4950 block)
No key input
(S1104)
DIGITAL EFFECT
(ME-4950 block)
No key input
(S1106)
PANEL NORMAL
(FP-129 board)
(S001)
PANEL CLOSE
(FP-129 board)
(S002)