Pentair Pool Products PacFab MiniMax 100 User & Installation Manual page 8

Table of Contents

Advertisement

Users Section
MILLIVOLT LIGHTING/OPERATION- NATURAL GAS & PROPANE
FOR YOUR SAFETY: READ BEFORE LIGHTING
If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal
injury or loss of life.
BEFORE OPERATING: Smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is
heavier than air and will settle on the floor.
Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the
appliance and to replace any part of the control system and any gas control which has been under water.
NEVER store any materials within the vicinity of the appliance or ventilation openings.
SAFETY INFORMATION - IF YOU SMELL GAS, FOLLOW THESE RULES
1.
Shut off gas line or propane tank.
2.
Immediately call your gas supplier
from a neighbour's phone.
3.
Follow the gas supplier's instructions.
4.
If you cannot reach your gas supplier,
call the fire brigade.
STOP! HAVE YOU READ THE SAFETY INFORMATION?
1. Push power switch off. Remove the front casing door. Twist the black knob on the gas valve anti-clockwise to
the pilot position and release it.
2. Make sure pump is running and primed.
3. Push in and retain fully depressed the black knob on the gas control. At the same time, repeatedly operate the
piezo spark generator to produce a spark at the pilot burner. When the pilot has been lit, keep the black knob
depressed for a further 20 seconds. If the pilot does not remain alight when the black knob is released, twist
the knob clockwise then release it. Wait at least three minutes then repeat the procedure from step 5.
4. In new installations where the gas line hasn't been bled, the pilot may be slow to light.
5. When this pilot flame is established, turn knob anti-clockwise and turn the power on. Set the thermostat to the
desired setting and the main burner should light. Refit casing door.
6. If the heater does not operate satisfactorily, consult the Troubleshooting Guide portion of this manual.
FOR SHORT PERIODS
Set the thermostat to its lowest setting, wait two minutes, then turn the power off. (Turn off all electric power to
the appliance if a service is to be performed.)
NOTE: The appliance is fitted with a thermo-electric flame failure device therefore the pilot and gas cock
must not be turned off except for long term shut-down, emergencies, or servicing.
If the appliance is to be turned off during a period when frost is likely, consult your service engineer/gas
supplier to take the appropriate action. (Drain the system.)
FOR LONG PERIODS
Set the thermostat to it's lowest setting, wait two minutes, then turn the power off. Twist the black button on the
gas valve clockwise then release it. Turn off the gas cock.
NOTE: If severe weather (frost) conditions are anticipated during a period, shutdown the heater and
system must be completely drained. Consult your service engineer/gas supplier to take the appropriate
action. (Drain the system.)
P/N 471438
WARNING
5.
Do not light matches or lighter.
6.
Do not try to light any appliance.
7.
Do not touch any electric switch;
do not use any phone in your building.
8.
Open all doors and windows. (Indoor)
TO LIGHT THE APPLIANCE
TO TURN THE APPLIANCE OFF
3
SIT Valve
On - Off Knob
Figure 1.
Rev. A 2-4-2000