Specifications - Pentair Pool Products PacFab MiniMax 100 User & Installation Manual

Table of Contents

Advertisement

SPECIFICATIONS - TECHNICAL DATA
(NATURAL GAS MODELS ONLY)
CATEGORY
GAS AND
SUPPLY PRESSURE
BURNER PRESSURE
HEAT INPUT
HEAT OUTPUT
GAS RATE
FLUE GAS VOLUME
(4.5% CO
, 100°C)
2
INJECTOR DIAMETER
& (MARKING)
NUMBER OF INJECTORS
(BURNERS)
MAXIMUM WATER PRESSURE
MAXIMUM WATER FLOW
TEMP
ELECTRICAL SUPPLY
WEIGHT (EMPTY)
NOMINAL FLUE DIAMETER
(INDOOR INSTALLATION)
P/N 471438
mbar
(in.wg)
GROSS
kW
(Btu/h)
NET
kW
(Btu/h)
kW
(Btu/h)
3
m
/h
3
m
/h
mm
bar (psi)
°C
kg
(lbs)
mm
(in.)
I
2H
G20 @ 20mb.
G20 @ 20mb.
9.3
(3.7)
29.3
(100,000)
(100,000)
26.4
(90,077)
23.4
(79,841)
2.8
88
14
230V - 50Hz
FUSED AT 5A. POWER 35W
38
125
(5)
I
2E
G20 @ 20mb.
G25 @ 25mb.
9.3
9.3 (3.7)
(3.7)
13.8 (5.5)
29.3
(100,000)
26.4
(90,007)
(90,007)
23.4
(79,841)
(79,841)
2.8
G20 - 2.8
G25 - 3.2
88
1.25
(125)
14
8
(125)
45
38
38.25
125
(5)
Rev. A 2-4-2000
ii
I
2E+
29.3
26.4
23.4
88
14
125
(5)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents