Hub To Backbone; Using Transceiver Interface Modules - 3Com 100 TX User Manual

3com hub user guide
Table of Contents

Advertisement

3-6
C
3: M
HAPTER

Hub to Backbone

Using Transceiver
Interface Modules
FMS 100-TX H
C
AKING
UB
You can connect hubs and hub stacks to the network backbone through
the transceiver interface module on the rear panel via a bridge, router, or
switch, using either Category 5 UTP or fiber cabling. Figure 3-6 shows
single and interconnected hubs connected to a network backbone.
100 meters maximum
100BT
1x
1x
1x
1x
1x
1x
1x
1x
1x
1x
1x
1x
ACTIVITY
LINE
PARTITION
1 2 3 4 5 6 7 8 9 10 11 12 13
Single hub
Figure 3-6 Connecting Hubs to the Network Backbone
Two types of transceiver interface modules are available for connecting the
LinkBuilder FMS 100-TX Hub to the LAN. By inserting the appropriate
transceiver interface module in the hub's thirteenth port, you can use either
UTP or fiber-optic cabling to connect the hub to various LAN devices. For
example, you can connect the LinkBuilder FMS 100-TX Hub to a multiport
bridge or switch using the 100-TX module and gain access to a 10BASE-T
network. Likewise, by using the 100BASE-FX module, you can attach the hub
to a switch that is connected via fiber cabling to the network. (See the next
section for a discussion of using the hub to access multisegmented networks.)
The required cabling for the two transceiver interface modules is as follows:
100BASE-TX module: Category 5 two-pair UTP cabling
100BASE-FX module: two-strand 62.5/125 multimode fiber cabling
Connections to a server or PC from one of the transceiver interface modules
require straight-through cabling.
ONNECTIONS
To network
backbone
®
LinkBuilder
STATUS
UNIT
3C12345
®
R
EPEATER
FAN FAIL
CLS2
OVERTEMP
CLS1
COLLISION
PWR
Switch, router, or bridge
100BT
STATUS
UNIT
3C12345
1x
1x
1x
1x
1x
1x
1x
1x
1x
1x
1x
1x
ACTIVITY
FAN FAIL
CLS2
LINE
OVERTEMP
CLS1
PARTITION
COLLISION
PWR
1 2 3 4 5 6 7 8 9 10 11 12 13
100BT
STATUS
UNIT
3C12345
ACTIVITY
FAN FAIL
CLS2
1x
1x
1x
1x
1x
1x
1x
1x
1x
1x
1x
1x
LINE
OVERTEMP
CLS1
PARTITION
COLLISION
PWR
1 2 3 4 5 6 7 8 9 10 11 12 13
100BT
STATUS
UNIT
3C12345
1x
1x
1x
1x
1x
1x
1x
1x
1x
1x
1x
1x
ACTIVITY
FAN FAIL
CLS2
LINE
OVERTEMP
CLS1
PARTITION
COLLISION
PWR
1 2 3 4 5 6 7 8 9 10 11 12 13
100BT
STATUS
UNIT
3C12345
1x
1x
1x
1x
1x
1x
1x
1x
1x
1x
1x
1x
ACTIVITY
FAN FAIL
CLS2
LINE
OVERTEMP
CLS1
PARTITION
COLLISION
PWR
1 2 3 4 5 6 7 8 9 10 11 12 13
Interconnected hubs
LinkBuilder
®
R
EPEATER
LinkBuilder
®
R
EPEATER
LinkBuilder
R
®
EPEATER
LinkBuilder
®
R
EPEATER

Advertisement

Table of Contents
loading

This manual is also suitable for:

Linkbuilder fms 100-tx