11.6 Powerful Mode Operation

When the powerful mode is selected, the internal setting temperature will shift lower up to 35.6°F (for
Cooling/Soft Dry) than remote control setting temperature for 20 minutes and the fan speed will increase to
achieve the setting temperature quickly.
Powerful operation stops condition
When one of the following condition is satisfied, powerful operation stops:
o
Quiet button is pressed.
Stop by OFF/ON button.
OFF Timer activates.
Powerful button is pressed again.
Powerful operation continue for 20 minutes.

11.7 Timer Control

11.7.1
ON Timer Control
ON timer can be set using remote control, the unit with timer set will start operate earlier than the setting time. This is
to provide a comfortable environment when reaching the set ON time.
60 minutes before the set time, indoor (at fan speed of Lo-) and outdoor fan motor start operate for 30 seconds to
determine the indoor intake air temperature and outdoor air temperature in order to judge the operation starting time.
From the judgment, the decided operation will start operation earlier than the set time as shown below.
11.7.2
OFF Timer Control
OFF timer can be set using remote control, the unit with timer set will stop operate at set time.
11.8

Random Auto Restart Control

When the power supply is cut off during the operation of air conditioner, the compressor will re-operate within
three to four minutes. There are 10 patterns to be selected randomly after power supply resumes.
This control is not applicable during OFF/ON Timer setting.
11.9

Indication Panel

LED
POWER
Color
Green
Light ON
Operation ON
Light OFF Operation OFF Timer Setting OFF Quiet Mode OFF Powerful Mode OFF
Note:
If POWER LED blinks, the possible operation of the unit is operation mode judgment, or ON timer sampling.
If TIMER LED blinks, there is an abnormal operation occurs.
Indoor intake air
temperature (°F)
86
77
TIMER
QUIET
Orange
Orange
Timer Setting ON
Quiet Mode ON
15 min
10 min
5 min
Outdoor air
86
95
temperature (°F)
Cooling / Soft Dry
POWERFUL
Orange
Powerful Mode ON
30