Page 1
Viking Installation Guide Viking Range Corporation 111 Front Street Greenwood, Mississippi 38930 USA (662) 455-1200 For product information, call 1-888-VIKING1 (845-4641) or visit the Viking Web site at vikingrange.com Side-By-Side & Bottom-Mount Refrigerator/Freezer F20605B EN (061410)
Table of Contents IMPORTANT– Please Read and Follow! Warnings & Important Information_____________________________________________________ 3 • Make sure that incoming voltage is the same Your safety and the safety of others is Professional & Professional Integrated Side-by-Side as unit rating. An electric rating plate very important.
Page 3
• make sure that you have these materials (not provided with your unit), which are necessary • Viking Range Corporation will NOT warranty any problems resulting from GFI outlets which for proper installation: are not installed properly or do not meet the requirements below.
Dimensions Specifications (Professional Side-By-Side) (Professional Side-By-Side) 42” Professional Side-By-Side 42” Professional Description VCSB542 VCSB542D Overall width 42” (106.7 cm) Overall height from bottom 82-3/4” (210.2 cm) min. to 84-1/16” (213.5 cm) max. Overall depth from rear To front edge of side trim: 22-3/16”...
Page 5
Dimensions Specifications (Professional Side-By-Side) (Professional Side-By-Side) 42” Professional Integrated Side-By-Side Description VISB542 VISB542D 42” Professional Integrated Overall width 42” (106.7 cm) Overall height from bottom 82-3/4” (210.2 cm) min. to 84-1/16” (213.5 cm) max. Overall depth from rear To front edge of side trim: 23-3/8”...
Cutout Dimensions Anti-Tip Dimensions (Professional Side-By-Side) (Professional Side-By-Side) 42” Professional 42” Professional & Professional Integrated Professional Anti-Tip Location Electric Outlet Location 6 ” Two 2”x 4” Mounting Boards (1 5 .2 c m ) 3” (7.6 cm) x 3-1/2” (8.9 cm) 9 ”...
Cutout Dimensions Anti-Tip Dimensions (Professional Side-By-Side) (Professional Side-By-Side) 48” Professional & Professional Integrated 48” Professional & Professional Integrated Professional Anti-Tip Location Electric Outlet Location 6 ” (1 5 .2 c m ) Two 2”x 4” Mounting Boards 3” (7.6 cm) x 3-1/2” (8.9 cm) 9 ”...
Page 8
Dimensions Specifications (Professional Bottom-Mount) (Professional Bottom-Mount) 36” Professional Bottom-Mount 36” Professional Description VCBB536 Overall width 36” (91.5 cm) Overall height from bottom 82-3/4” (210.2 cm) min. to 84-1/16” (213.5 cm) max. Overall depth from rear To front edge of side trim: 22-3/16”...
Cutout Dimensions Anti-Tip Dimensions (Professional Bottom-Mount) (Professional Bottom-Mount) 36” Professional & Professional Integrated 36” Professional & Professional Integrated Professional Anti-Tip Location Electric Outlet Location 6 ” (1 5 .2 Two 2”x 4” Mounting Boards c m ) 3” (7.6 cm) x 3-1/2” (8.9 cm) 9 ”...
Cabinet Information Cabinet Information (Professional) (Professional) Professional models fit “semi-flush” in standard 24” (61.0 cm) deep cabinet openings. The door Professional models fit “semi-flush” in standard 24” (61.0 cm) deep cabinet openings. The door face protrudes 2-1/2” (6.4 cm) from the cabinet face. The handle protrudes an additional face protrudes 2-1/2”...
Page 11
Cabinet Information Cabinet Information (Professional Integrated) (Professional Integrated) Professional Integrated models fit flush in standard 24” (61.0 cm) deep cabinet openings with no Professional Integrated models fit flush in standard 24” (61.0 cm) deep cabinet openings with no protrusion into the room except the handle protrudes 2-1/2” (6.4 cm) into the room. protrusion into the room except the handle protrudes 2-1/2”...
Cabinet Information Cabinet Information (Designer) (Designer) Designer models fit flush in standard 24” (61.0 cm) deep cabinet openings with no protrusion into the Designer models fit flush in standard 24” (61.0 cm) deep cabinet openings with no protrusion into the room except 2-1/2”...
DO NOT tubing to the unit, flush at least 2 quarts • The installation of Viking units with a have a fuse in the neutral or grounding (1.9 L) of water through the copper tubing •...
Installation General Information • Most of the unit’s weight is at the top. TIP OVER HAZARD Extra care is needed when moving the unit Appliance is top heavy and tips easily to prevent tipping. when not completely installed. Keep doors closed until appliance is •...
Hinge Adjustment Front of unit Plug in power cord to verify operation. Place unit within 3” of being flush with cabinets. Remove four side screws and remove unit top. Loosen the four hinge screws. Adjust door. NOTE: Make sure power switch is in the “On” Position. Retighten four hinge screws.
Door Stop Adjustment (Side-by-Side) 90˚ 110˚ 120˚ Turn on water supply and check for leaks. Lift unit off rollers to desired height and level unit using Open refrigerator door so door stop and shoulder Remove shoulder screw and place in 90° or a 5/16”...
Water Filter Installation (Side-by-Side with Dispenser) Water Filter System Specification and Performance Data Sheet This system has been tested according to NSF/ANSI 42/53 for reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration of less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42/53.* (100% safety factors built- in for unmetered usage for health claims only.) NSF Specified...
Final Installation Performance Checklist Replace top air grille. Using an 8” magnetic nut driver, replace the two 1/4” screws. (Professional) Replace the center grille louver. (Designer) Replace the center grille louver. h Verify cabinet size. h Align/square door(s). h Verify drain pan is properly installed and h Verify electrical supply and water supply no leaks on water connection.
Service & Registration Verify Operations Control Panels Only authorized replacement parts may be used in performing service on the appliance. Bottom Mount Do not repair or replace any part of the appliance unless specifically recommended in the manual. All other servicing should be referred to a qualified technician.