ADJUSTMENT

Audio Section
Adjusting Idling Current
Required measurement equipment: DC Voltmeter
1. Preparation
(1) Temperature should be at avoid direct blow from an air conditioner or an electric fan and humidity should be moderate,
and place the set at normal usage environment.
15 °C ~ 30 °C (59 °F ~ 86 °F)
(2) Presetting
POWER (Power source switch)
SPEAKER (Speaker terminal)
(Do not connect speaker, dummy resistor, etc.)
2. Adjustment
(1) Remove the top cover and set VR401, VR402, VR403, VR404, VR405, VR406, VR407 on at fully 7CH AMP UNIT at
fully counterclockwise ( c ) position.
(2) Connect DC Voltmeter to test points (FRONT-Lch: TP401, FRONT-Rch: TP402, CENTER ch: TP403, SURROUND-
Lch: TP404, SURROUND-Rch: TP405, SURROUND-BACK Lch: TP406, SURROUND-BACK Rch: TP407.
(3) Connect the power cord to AC Line, and set the power switch to "ON".
(4) Presetting.
MASTER VOLUME
SPEAKER (Speaker terminal) : No load
(Do not connect speaker, dummy resistor, etc.)
MODE
FUNCTION
(5) Within 2 minutes after the power on, turn VR401 clockwise ( x ) to adjust the TEST POINT voltage to
6.5mV ± 0.5mV DC.
(6) After 10 minutes from the preset above, turn VR401 to set the voltage to 8.0mV ± 0.5mV DC.
(7) Adjust the Variable Resistors of each channel in the same way.
DC Voltmeter
VR401
STANDBY
No load
: "---" counterclockwise ( c min.)
: MCH STEREO
: DVD
7CH AMP UNIT
VR404
VR403
TP404
TP401
S Lch
F Lch
TP403
VR402
VR405
TP405
C ch
S Rch
74
VR407
VR406
TP402
TP406
F Rch
S Back Lch
TP407
S Back Rch

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Avr-x2000

Table of Contents