6-4 Before replacing the LCD/Lens prism
You should not separately replace the parts of the liquid crystal LCD/Lens prism because they only work properly
when used together. Therefore, you can either replace the LCD/Lens prism assembly or send the whole
LCD/Lens prism assembly unit back to HITACHI where we will replace the malfunctioning part,
recondition the device and send it back to you.
DISTRIBUTOR
6-5 Cleaning dust from panels and optical filters
1. Preparation
Prepare cleaning tools and materials as follows. Work in a relatively clean room so as to remove
additional dust while in removal operation.
(1) Swab for cleaning • • • • • • P#: NX08061, "Cotton stick L147"
(2) Air duster (Dust blower, spray can)
(3) Vacuum cleaner
2. Disassemble and open the maintenance hole.
(1) Turn off the projector, and unplug the power cord.
(2) Remove the top cover, according to the disassembling diagram of chapter 8.
(3) Remove the MAIN board, according to the Chapter 6-2.
(4) Remove the intake LID.
Handling FPC cable
Be careful not to add strong load, such as pulling or twisting the FPC cable.
If load is added to FPC cable, Convergence may shift.
When the FPC cable is being removed, attached, when opening or closing a intake LID, perform the operation
carefully and slowly so that load is not added to FPC cable.
(5) Re-assemble the MAIN board and re-connect all the connectors.
CP-S235 (C10SM2)
Do not disassemble the unit
because replacement of separate
parts is not possible.
Return
ATTENTION
Release two latches
18
HITACHI
Replacement of G Panel
Intake LID
Lift
FPC cable
G Panel