SM Series Heat Pump
Required steps
How to use this table:
Select desired configuration
from "possible unit
configurations".
Instructions with "X" have to
be performed to reconfigure
the unit.

ACCESS TO INTERNAL COMPONENTS

(PG#15)
BLOWER RE-CONFIGURATION (PG#17)
E-BOX CONFIGURATION (PG#24)
ELECTRIC HEAT RELOCATION* (PG#22)
CONDENSATE DRAIN RELOCATION
(PG#20)
HRP SWITCH* (PG#21)
REINSTALL PANELS (PG#25)
*APPLIES IF OPTION IS INSTALLED
[1] AIR COIL
[2] E-BOX (UNIT FRONT)
[3] BLOWER
X APPLICABLE STEP
All heat pumps are supplied with panel belt
which needs to be removed to access screws
for panel removal. The panels have additional
internal fasteners to prevent any air leakage.
For safety precautions two persons are
required to perform this operation.

Required Tools

5/16" hex head driver
3/8" hex head driver
7/16" hex head driver
Flat screw driver
Phillips screw driver
1/4" hex head driver
Needle nose pliers
Revised 02-15
Possible unit configurations
Right return,
Left return,
top
top discharge
discharge
X
X
X*
X
X*
X*
X
Access to Internal Components
1. Using a Flat Screw driver remove and retain
Panel Belt by inserting the screwdriver into the
slot and releasing the catch.
(Figures#42and#43)
Vertical Configurability | 15
Right return,
Left return,
Right
rear
return, rear
discharge
discharge
X
X
X
X
X
X
X*
X
X
The belt is held in place by a clip on one side
and an interference fit on the other end.
Figure # 42
Left return,
left
right
discharge
discharge
X
X
X
X
X
X
X*
X
X
6 720 220 406 (2015/02)