Installing Vent Components (Figure 59)
Begin the vent system installation by installing the first Simpson
Duravent component, 90° elbow to the starting collars or straight
pipe on the top of the appliance, then the straight pipe length and
then horizontal or vertical termination kit.
NOTE: All outer connection joints must be sealed with aluminum
tape, screws or silicone sealant rated above 300°F/149°C. The
inner flue joints do not require any sealant.
Simpson Duravent vent system components lock into place by sliding
the concentric pipe section with four (4) equally spaced interior beads
Figure 59
28649-2-0811
VENT SYSTEM IDENTIFICATION
Special Venting Components (Simpson Duravent)
See Empire Comfort Systems Retail Price List for Simpson Duravent part
numbers and pricing.
DVVK-5RP
(DVVK-5R)
DVVK-5TP
(DVVK-5T)
DVVK-5VP
(DVVK-5V)
DVVK-5TS
DVVK-5F
onto the appliance collar or previously installed component end with
four (4) equally spaced indented sections. When the internal beads
of each starting outer pipe line up, rotate pipe section clockwise 90°
(approximately 3 inches). The vent pipe is now locked together.
Continue adding components per the pre-planned vent system
configuration. Be certain that each succeeding vent component
is securely fitted and locked into the preceding component in the
vent system.
WALL THIMBLE
(MAXIMUM OF
TWO 90 ELBOWS)
Special DV Vent Kits
Available from Empire Comfort Systems, Inc. dealers.
Direct-Vent Fireplace Vent Kit for Rear Vent, 6 to 12 inch wall
thickness, Includes SD-1208, SD-1247, and SD-1284
Direct-Vent Fireplace Vent Kit for Top Vent, Thru-the-wall, 4 to 6
inch wall thickness, Includes SD-1290, SD-1284, SD-1208 and
SD-1247
Direct Vent Fireplace Vent Kit - Vertical, Includes SD-1291, SD-
1253, and SD-1243
Top Vent Kit (Horizontal) - 4½" to 6" wall thickness (114.3mm to
152mm)
Horizontal Flex Vent Kit (4' Flex) (1.22m)
(MAXIMUM OF
THREE 90 ELBOWS)
Page 37