GE GXSF30V Owner's Manual & Installation Instructions page 20

Table of Contents

Advertisement

Available languages

Available languages

Programming the Water Softener.
POWER OUTAGE MEMORY
If electrical power to the water softener is lost,
"memory'' built into the timer circuitry will keep
all settings for up to 24 hours. While the power
is out, the display is blank and the water softener
will not regenerate. When electrical power is
restored, the following will occur:
Reset the present time only if the display is
flashing. The HARDNESS and RECHARGE TIME
never require resetting unless a change is desired.
Even if the clock is incorrect after a long power
outage, the softener operates as it should to keep
your water soft. However, regenerations may
occur at the wrong time of day until you reset the
clock to the correct time of day.
NOTE: If the water softener was regenerating
when power was lost, it will now finish the cycle.
BLUE INDICATOR LIGHT
Steady blue light indicates that the unit is working
correctly. The light flashes when the unit needs
attention from the user.
been interrupted. Check the PRESENT TIME
setting.
check salt level and add salt as required.
problem with system (see page 25).
DAYS TO EMPTY flashes -
Err is in the display - electrical
LOW SALT SIGNAL
When the DAYS TO EMPTY drops to 15, the blue
indicator light and DAYS TO EMPTY in the display
will flash every second and the alarm will beep
every 30 seconds (from 8:00 AM to 8:00 PM), to
notify the user that the unit is running low on
salt. As soon as any button is pressed, the alarm
will stop beeping. The blue indicator light and
DAYS TO EMPTY will continue to flash. Once salt
is added to the brine tank and the SALT LEVEL is
reset, the DAYS TO EMPTY will be reset.
ERROR SIGNALS
If there is an error code
detected, the blue
indicator light will flash
4 times every second,
the display will flash Err
and the alarm will beep
every 30 seconds (from
8:00 AM to 8:00 PM) to signal that the softener
requires service. The alarm can be turned off by
pressing any button, but the blue indicator light
and display will continue to flash.
Disconnect the transformer from the wall outlet
momentarily, and plug it back in. The normal
display will appear. The motor may run for several
minutes, as the unit resets. If the problem is
not corrected, the error code will reappear in
8 minutes. See the Before you Call for Service
section to assist in troubleshooting the water
softener.