Advanced troubleshooting for service.
Service: Manually Advance Recharge Check
NOTE: The control display must show a steady time (not
flashing).
1. Press the RECHARGE button and hold in for three
seconds. RECHARGE NOW begins to flash as the
water softening system enters the fill cycle of
recharge. Remove the brinewell cover and, using a
flashlight, observe fill water entering the brine tank. If
water does not enter the tank, look for an obstructed
nozzle, venturi, fill flow plug or brine tubing. See Care
and Cleaning of the Water Softener System section.
2. After observing fill, press the RECHARGE button to
move the water softening system into brining. A
slow flow of water to the drain will begin. Verify brine
draw from the brine tank by shining a flashlight into
the brinewell and observing a noticeable drop in the
liquid level over an extended period of time (15 to 20
minutes).
NOTE: Be sure a salt bridge is not preventing water from
contacting salt. See Care and cleaning of the water
softening system section.
If the water softening system does not draw brine, check:
nozzle and/or venturi dirty or defective.
defective nozzle and venturi seal.
nozzle and venturi not seated properly
on gasket.
other inner valve defect (rotor seal, rotor and disc,
wave washer, etc.).
restricted drain (check drain fitting and hose).
NOTE: If water system pressure is low, an elevated drain
hose may cause back pressure, stopping brine draw.
3. Again, press the RECHARGE button to move the water
softening system into backwash. Look for a fast flow
of water from the drain hose. A slow flow indicates a
plugged top distributor, backwash flow plug or drain
hose.
4. Press the RECHARGE button to move the water
softening system into fast rinse. Again look for a fast
drain flow. Allow the water softening system to rinse
for a few minutes to flush out any brine that may
remain in the resin tank from the brining cycle test.
5. To return the water softening system to service, press
the RECHARGE button.