Philips Perfect Draft HD3610/50 Service Manual

Philips Perfect Draft HD3610/50 Service Manual

Hide thumbs Also See for Perfect Draft HD3610/50:

Advertisement

Philips Domestic Appliances and Personal Care
Service Manual
PRODUCT INFORMATION
- This product meets the requirements regarding
interference suppression on radio and TV.
- After the product has been repaired, it should function
properly and has to meet the safety requirements as
officially laid down at this moment.
Published by Philips Domestic Appliances and Personal Care
07/10
TECHNICAL INFORMATION
- Power
- Power consumption :
- Cool down period average
(KEG 23 °C -> 3 °C)
- Standby period
(KEG on 3 °C)
- Voltage
- Flow rate
- Contents Keg
- Colour setting
- SAP coding
OPTIONAL (accessories)
- No specific issues
Printed in the Netherlands
© Copyright reserved
Perfect Draft
HD3610/50
: 70 W
: 0.062 kWh
: 0.042 kWh
: 100 - 120 V - 50/60 Hz
200 - 240 V - 50/60 Hz
: 2 L per minute
: 6 L
: Select Grey
: HD3610/50
Subject to modification

Advertisement

Table of Contents
loading

Summary of Contents for Philips Perfect Draft HD3610/50

  • Page 1 - Contents Keg : 6 L - Colour setting : Select Grey - SAP coding : HD3610/50 OPTIONAL (accessories) - No specific issues Published by Philips Domestic Appliances and Personal Care Printed in the Netherlands © Copyright reserved Subject to modification 07/10...
  • Page 2 DISASSEMBLY- AND RE-ASSEMBLY ADVISE HD3610/50 For your safety first be sure the plug is Replacing the Peltier element: disconnected from the mains! - When the Peltier element has to be replaced, first remove the back cover and Fan assy. Removing the back cover: - Unscrew the 2 screws located on the heat sink.
  • Page 3: Repair Instructions

    REPAIR INSTRUCTIONS HD3610/50 Electrical circuit: - When the appliance does not work, check the electrical circuit. Beer outlet Process block diagram of the appliance Pressure Sensor Keg fill air Air inlet pump release Compressed 10.5 V Interface board Keg present (rear panel) Power supply switch...
  • Page 4 REPAIR INSTRUCTIONS HD3610/50 Service testroutines - This appliance has been equipped with special service routines to be able to check several functions of the appliance. - Below the necessary steps will be described to enter into the service mode. - Please follow the instructions carefully to avoid damaging the electronic circuit of the appliance. Putting the appliance into Service test mode.
  • Page 5 REPAIR INSTRUCTIONS HD3610/50 Stepmode Test Stimulus Response Remark (Press & release KEG switch) Temperature test NTC simulated value LED lights up: Replace NTC sensor by dummy sensor. Disconnect NTC (J6) 1. 1 kΩ (1%) from the PCB. Apply to (J6) below 2.
  • Page 6 REPAIR INSTRUCTIONS HD3610/50 Procedure for checking cool down performance Peltier element. - To ensure the Cool performance of the Peltier element is according specification the below test procedure have to be carried out. Preparations: 1. Switch the appliance off and let it stabilize until it reached room temperature. 2.
  • Page 7: Troubleshooting

    TROUBLE SHOOTING HD3610/50 Problem Cause Repair solution 1 Appliance doesn’t work 1. Power supply failed. 1. Check voltage output 10 V ± 0.5 V. (replace power supply) 2. Keg present switch failed. 2. Check/replace micro switch. 2 Blinking RED LED LED indication Software detection: no tap unit / air leakage...
  • Page 8: Condensation Water

    TROUBLE SHOOTING HD3610/50 Problem Cause Repair solution 6 Beer leakage. 1. Leakage spout side. 1. Check beer tube on hairline cracks or check closing mechanism tap unit. 2. Leakage on top of the Keg. 2. Check beer tube, tap unit and Keg. 7 Condensation water Through the cooling process condensation 1.