Installation Below A Countertop - Monogram ZJ7000 Installation Instructions Manual

Electric warming drawer
Hide thumbs Also See for ZJ7000:
Table of Contents

Advertisement

INSTALLATION BELOW A COUNTERTOP

Install 2x4 or 2x2 Anti-Tip Block
Against Rear Cabinet Wall 9"
From Floor to Bottom of Block
Electrical
Outlet 16"
Max. From
Left Side
23-1/2" Min.
• When installed, the front face of the drawer will be
nearly flush with adjacent cabinetry doors.
• Drawer overlaps will conceal cut edges on all sides of
the opening.
The rough opening for the drawer must be:
– Depth: 23-1/2" min. from inside back to front of cabinet
frame.
– Width: 25-1/2" for 27" wide models,
28-1/2" for 30" wide models.
– Height: 9-1/4".
• 5" min. above floor or 1" above toekick. 23-1/4"
from floor to bottom of cutout is recommended for under
countertop installation.
Installation below a cooktop:
Warming drawers are approved for installation below only
certain specified cooktop models. See the label attached
to the top of the warming drawer for approved models. A
solid barrier and air gap between cooktop and warming
drawer is required. See Note above.
Installation Preparation
Electrical Outlet
Flush With Side of
Cabinet 7" Max.
7"
9"
Solid Barrier
1/4"
Air
Gap
Install a Solid Barrier
and a 1/4" Air Gap
Above Warming Drawer
Electrical Outlet 42"
Max. From Right Side
1-1/2" Cabinet Top
25"
Install a Solid Barrier
Below a Cooktop
See Note
1" Min.*
9-1/4"
A
*NOTE: When installing the warming drawer below a cooktop, a solid barrier
must be installed at least 1" from the lowest point of the bottom of cooktop
burner box to the top of cutout. Use any solid material such as 1/4" thick
plywood. Allow at least 1/4" air gap between the barrier and the top of the
warming drawer. See label on top of the warming drawer for approved
cooktop models.
Installation below a cabinet drawer:
The warming drawer may be installed beneath a cabinet
drawer. In this installation, a solid barrier should be installed
above the warming drawer to block access. Use any solid
material such as 1/4" thick plywood. Allow at least 1/4"
air gap between the barrier and the top of the warming
drawer. Observe the 5" min. above the floor or 1" above the
toekick minimum installation height.
NOTE: If you are installing in frameless cabinets, it may
be necessary to install 1/2" wide cleats to accept drawer
mounting screws. See drawer to find exact locations of
mounting screws.
Side to Side Installation:
Install two warming drawers in separate cutouts.
Allow 2" min. between cutouts.
Side to Side Installation
8
36"
Countertop
Height
Dimensions
ZW9000
28-1/2"
ZJ7000
25-1/2"
2"
Min.