Control Elements
channel where you inserted the plug contains a signal that is loud
enough to ensure correct processing.
OUTPUT GAIN control to reduce the output level if the OVL-LEDs
keeps flashing.
8

OUTPUT GAIN

The OUTPUT GAIN control allows you to reduce the
output signal by up to -20 dB or boost it by up to
+6dB. This ensures that following devices receive
an optimized level. The center position at 12-o'clock
equals 0 dB output. If the OVL-LEDs keeps flashing
you have to reduce the output level to avoid internal
clipping.

SIG. LED

The SIG. (signal) LED indicates the presence of an audio sig-
nal. In the analog world this LED helps the operator especially
in complex setups to determine immediately if the device
receives any signal. In the digital domain it tells you that the

OVL LED

The OVL (overload) LED indicates internal clipping. Whether
the clipping is audible or not depends on the kind of audio
material you are processing.