IMPORTANT SAFETY INSTRUCTIONS 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water. 6. Clean only with dry cloth. 7. Do not block any ventilation openings. Install in accordance with the m anufacturer’s instructions.
CONTENTS OF PACKAGE The package contains the following Camera in Housing ------------------------------------------------------------------1 Instruction Manual (This Document) --------------------------------------------1 Accessory Kit for Installing ---------------------------------------------------------1 Drilling guide label -------------------------------------------------------------------1 TABLE OF CONTENTS INTRODUCTION --------------------------------------------------------------------------------------- 4 CAMERA CONNECTIONS -------------------------------------------------------------------------- 5 INSTALLATION ----------------------------------------------------------------------------------------- 6 LENS ADJUSTMENT --------------------------------------------------------------------------------- 8 DC AUTO IRIS LENS --------------------------------------------------------------------------------- 8 OPERATING CAMERA ------------------------------------------------------------------------------- 9 CAMERA ADJUSTMENT ---------------------------------------------------------------------------- 9...
INTRODUCTION The camera provided high-quality image using SONY Wide Dynamic 1/3” Super-HADII PS 960H CCD and digital signal processing LSIs. Features: • 1/3” Super-HADII PS 960H CCD • Super high-resolution of 650TV lines • 0.4 lux(Color), 0.04 lux(B/W), 0.001 lux(Low-Shutter) @ F1.4 Sensitivity •...
CAMERA CONNECTIONS Connection Cable Description COLOR Description AC24V/DC12V WHITE AC24V/DC12V ORANGE ADKEY BROWN BLUE RS485(-) GREEN RS485(+) YELLOW ALARM OUT GRAY DN EXT-IN BLACK&WHITE DN EXT-OUT BLACK SKY BLUE UTP+(optional) PINK UTP- (optional) 1) External Day/Night Control : To select Day/Night mode using external equipment, by connecting control lines to the appropriate terminals.
5) UTP (optional) Video signal through out the UTP Cable (SKY BLUE(+) & PINK(-) ) 6) External AD Key Control (optional) 95mm Black/GND GND Terminal/Brown 45mm AD Key Terminal/Orange White/AD output Remote Control (optional) INSTALLATION 1. Loosen the four torx screws located midway up the front of the housing leave the screws intact in the front portion.
Page 7
Ceiling Drilling Guide Label Mounting Screw M6X35(4x) Plastic Anchor(4x) Figure 3 Rubber Washers(4x) Electrical box MOUNTING HOUSING TO AN ELECTRICAL BACK BOX The housing can also be mounted on a 4s or 2s electrical box. Torx screws UNC 8-32 x 0.75...
LENS ADJUSTMENT Field of view: Adjust setting from Telephoto (T) to wide (W) field of View. Focus: Adjust lens focus from near (N) to infinity. DC AUTO IRIS LENS 2.6-6mm 4-9mm 2.8~12mm 6-50mm 1/3” CCD 1/3" CCD 1/3" CCD 1/3" CCD Image Size Focal Length 2.6-6.0mm...
OPERATING CAMERA ① Enter Button ② Up Button ③ Down Button ④ Left Button ⑤ Right Button ⑥ Spot Video Output ⑦ UTP(Optional) CAMERA ADJUSTMENT <White Balance> 1) Auto(Auto White Balance) : AWB mode (1800ºK ~10500ºK) 2) Push/Hold : Push&Hold Mode. ...
Page 10
excessive lighting compensation is performed when the weighting on the high-brightness side is increased. 4) Auto(Auto Weighting BLC) : Auto weighting BLC on. 5) Spot(User Setting BLC area) : Spot metering mode on. Posi : OSD mode to adjust the position of the spot metering area. ...
Page 11
The result of face trace can be inaccuracy. 5) Mine : Mine area mode. By this function, User can draw motion detection area with free dotting Set Mine : Press the Enter button to Set Mine mode. <...
Page 12
8) Entrance : Entrance counting mode. The object move in through the entrance, counting number increases. Size : Press Enter button adjust the size of the Entrance zone. Posi : Press Enter button adjust the Position of the Entrance zone. ...
Use the Up and Down buttons adjust to digital tilt Press the Enter button to exit. PT Reset(Pan & Tilt Reset) : Press the Enter button to reset digital pan and tilt. 4) Freeze : Select the still mode on/off 5) Frame Control: Select term of refres h rate for output video.
Page 14
Baud Rate : Select serial communication spe Baud Rate : Select serial communication spe ed (2400/4800/9600/19200). ed (2400/4800/9600/19200). Protocol : RS-485 protocol. (COMMAND/FASTRAX/PELCO-D/Pelco-D) Protocol : RS-485 protocol. (COMMAND/FASTRAX/PELCO-D/Pelco-D) Title : Edit camera title. Title : Edit camera title. Title Site_0 ☞<...
Page 15
Activate only AC power inputted. 5) White Pixel Det Exe : Press Enter button to turn White Pixel Compensation mode Start. ENT to Adj : Press Enter button to start White Pixel Compensation start. Proc : Process to find white pixel. ...
SPECIFICATIONS MODEL NTSC PAL Image sensor 1/3" Super‐HADII PS 960H CCD Effective pixels 976x494 976x582 G Scanning system 2:1 interlace E Scanning frequency 15.734KHz(H), 59.94Hz(V) 15.625KHz(H), 50Hz(V) N Sync. system Internal / Line lock E Resolution 650 TVL R Min. illumination 0.4 Lux (COLOUR), 0.04 Lux (B/W), 0.001 Lux (Low‐shutter) A Video output 1.0 Vp‐p (75 ohm, composite) L S/N Ratio 50dB (AGC OFF) Camera Control RS485 (Faxtrax, Pelco D, Pelco P) White Balance Auto / CRS / Push&Hold / Indoor / Outdoor / FL / User Exposure Auto / Manual Shutter / Flickerless/ Low Light Control / Offset Add BLC/WDR EHLC / AUTO / SPOT / ZONE/ BLM WDR: x512 (Level Adjust) AGC Control Low / Middle / High / Off ...
Need help?
Do you have a question about the VD650WDR and is the answer not in the manual?
Questions and answers