2.13.5 How to program a controller using an Emerson "Hot Key" (download)
Turn the controller off.
Insert a pre-programmed "Hot Key" into the 5-pin receptacle and turn the controller on.
The parameter list of the hot key will be automatically downloaded into the controller
memory. The "doL" message will blink followed a by a flashing "End" label.
After 10 seconds the controller will restart working with the new parameters.
Remove the "Hot Key".
NOTE: The message "Err" is displayed in case of a failed programming operation. In this
case turn the unit off, then on again if you want to restart the download, or remove the
"Hot Key" to abort the operation.
2.14 Troubleshooting
2.14.1 Alarm menu
The controller records in the Alarm menu the total number of alarm activations (max 50)
according to the alarm list in Appendix 5.
Action
Key or display
Enter menu
Waiting for action
Enter section list
Select active alarm
code from list
Select the alarm to
see the detailed rtC
information
Select detailed
information from
active alarm list
Exit menu
Table 19: How to check the alarm list
18
Notes
Push and release the ALR key.
The menu to change the section will be entered. The
SEC
alarm list section is active.
Press SET to confirm. The following list will be
available to select the proper network function.
Scroll the list of alarms and see the list of active
alarms with the number of the alarm (letter + number,
A01-A50).
or
Press
Press
Enter the sub menu with alarm time details.
With the rtC activated:
The Hur (hour) parameter is displayed.
Press
Press
Press
Press
Press
Press
Press
Press
or
Press
Note: The clock info indicates the START time of the
alarm.
Without the rtC activated:
The COn (hours) parameter is displayed.
Press
To exit: press
pressing any key.
Press
seconds without pressing any key.
and see the alarm name or code.
and see the next active alarm.
and see the alarm hour.
and see the Min.
and see the alarm min.
and see the dAy.
and see the alarm day.
and see the Mon(day) parameters.
and see the alarm month.
and see the alarm YEA.
and see the alarm year.
and see the compressor working hours.
or wait for 15 seconds without
simultaneously or wait for about 10
C6.1.6/0513-0515/E