Service items
23
EEPROM error of each unit
(Hexadecimal)
24
Drum ID
25
Serial interface information
26
Drum sensitivity information
27* Calibration table settings
28
Optional paper feeder information
29
Average print density (%)
30
Operation panel message language
31
Current temperature
32
Current humidity
33* Number of rebooting for vertical distortion
check
34* MAC address
35
Media type attributes
36
SPD information (slot 1)
37* SPD information (slot 2)
38
Engine parameter setting
39
Drum serial number
40
Machine serial number
Item
Description
Bit 0: Ppaer feeder 1
Bit 1: Paper feeder 2
Bit 2: Paper feeder 3
Bit 3: Duplexer
Bit 4: Sorter
Bit 5: Bulk paper feeder
Bit 6: (Reserved)
Bit 7: Drum
-
RS2: RS-232C
-
Setting value (FRPO I4), Hexadecimal
First 2 bytes
Bit 0: MP tray
Bit 1: Cassette 1
Bit 2 to 6: Paper feeder 1 to 5 (4 and 5 Reserved)
Bit 7: Duplexer
Bit 8: Bulk paper feeder
Bit 9: Envelope feeder
Bit 10 to 15: (Reserved)
Second 2 bytes
Bit 0: Face-up
Bit 1: Face-down
Bit 2: (Reserved)
Bit 3: Sorter
Bit 4 to 15: (Reserved)
2 digits of integer part and 1 digit of fraction part
(total print density from shipping from factory)
PMSG command setting value (decimal)
0 to 80 °C
("-" = Humidity/temperature sensor is abnormal.)
5 to 100 %RH (in 1% increment)
-
-
Media type 1 to 28 (14 to 20: Reserved)
2 to 6 bytes, 8 to 36 bytes, 94 to 95 bytes (total 32 bytes)
2 to 6 bytes, 8 to 36 bytes, 94 to 95 bytes (total 32 bytes)
-
-
-
Description
1
*
: FS-3820N/3830N models only.
2FP/2FY/2FR-6
1-4-5