Siemens RDE100.1RFS Operating Instructions page 4

Advertisement

Does symbol
appear on the display?
is displayed when the batteries are low.
Symbol
Replace them with 2 new alkaline batteries type AAA.
Proceed as follows:
·
Get 2 new alkaline batteries type AAA
·
Remove the battery holder and then the batteries.
Insert the new batteries and, within 1.5 minutes,
replace the battery holder
·
Ensure the exhausted batteries are disposed of
correctly, in compliance with environm ental
requirements
Do you want to lock the keypad?
Mode
Press and hold Mode for at least 7 seconds to
activate a button lock. Repeat to unlock.
The unit operates normally when the buttons
are locked, but changes cannot be made.
Receiver's LED indication
State of receiver
State of LED
Power up (or reset)
The red and green LEDs flash
alternately for 5 seconds, then
change to constantly red.
Note: If the receiver was previ-
ously programmed, it shows
immediately constantly red.
Learning mode
The red and green LEDs flash
alternatively.
Successful learning
If RCR100RF learning is
mode
successful, the green LED will
flash for 10 minutes.
Signal ok and
The green LED is constantly lit,
output status
and if the output status
change
changes, the green LED flashes
for 3 seconds, then changes
back to constantly green.
Fail to receive
If the RCR100RF fails to receive
wireless data
wireless data, the red LED will
start to flash after 125 minutes.
If the RCR100RF signal is
recovered, it will return to the
previous LED state.
Do you want to change parameters?
+
If you want to change control parameters,
proceed as follows:
·
+
Press
and
Ok
seconds
Mode
·
Release the buttons and parameter
P01 is displayed on the bottom
segment
·
+
Press
or
that needs to be changed
·
Press Ok to select the parameter
·
+
Press
or
·
Press Ok to confirm the changed value
·
Press Mode to exit the parameters
without saving or wait for the program
to exit automatically
4/4
Operating Instructions
simultaneously for 5
to scroll to the parameter
to change the value
CB1B1425en_01 / 2014-11-26
Parameter list
Parameter
Description
no.
P01
Time format
P02
Selection of °C or
°F
P03
Standard
temperature display
P04
Temperature
sensor calibration
P06
Comfort setpoint
lock
P08
Economy setpoint
lock
P09
Buzzer
P10
Show frost
protection icon
P11
Time switch type for
Auto Timer
P12
Periodic pump run
P14
X1 external input
P15
Temperature
limitation
P16
Max. limitation
temperature for
floor heating
P17
Window contact
features
P19
Sequential number
of room unit
P20
RF learn
P21
Scanning rate for
the capacitive
buttons
Note: Shorter
scanning rate
means shorter
battery life
P22
Reload factory
settings
P23
Software version
information
Siemens Building Technologies
Setting range
(default)
1 = 24:00 hours
(default)
2 = 12:00 am/pm
1 = °C (default)
2 = °F
1 = room temperature
(default)
2 = setpoint
-3...3 °C
Step 0.5 °C
(-6...6 °F, step 1 °F)
Default: 0 °C
0 = OFF (default)
1 = ON à locked
according to setting
in permanent
temperature setpoint
0 = OFF (default)
1 = ON à locked
according to setting
in permanent
temperature setpoint
0 = OFF
1 = ON (default)
0 = OFF (default)
1 = ON
0 = individual days
(default)
1= all 7 days
2= 5-2 days
0 = OFF (default)
1 = ON
0 = no input (default)
1 = external sensor
2 = digital input
0 = OFF (default)
1 = ON
35...60 °C, step 1 °C
or
95...140 °F, step 1 °F
Default: 55 °C
0 = normally open
contact (default)
1 = normally closed
contact
0 = no display of
zone (RF off)
1 = zone number 1
(for standard RF)
(default)
6 = zone number 6
0 = OFF (default)
1 = ON
0.2 = 0.25 s
0.5 = 0.5 s
1.0 = 1.0 s (default)
1.5 = 1.5 s
0 = OFF (default)
1 = reload
No adjustment
possible