Heatrae Sadia Megalife 100E Installation Manual page 17

Table of Contents

Advertisement

Table 04: Unit weights
Table 05 - Standing Heat Loss
Standing heat losses
(based on an ambient air temperature of 20°C and a stored water temperature of 65°C)
Model(s)
Energy efficiency class
Storage volumes V in Litres
Standing loss in W
Table 7: Technical parameters in accordance with European Commission regulations 814/2013 and 812/2013
Name
Model
Volume Litres
V40
Load Profile
Energy Efficiency Class
Energy Efficiency %
Annual electricity consumption kWh
Daily fuel consumption kWh
Thermostat setting
Specific precautions that shall be taken when the
water heater is assembled, installed or maintained and
disposed of at end of life
Table 7: Technical parameters in accordance with European Commission regulations 814/2013 and 812/2013
Nominal
Model
Type
Capacity
Reference
(litres)
Indirect
100 B
120 B
150 B
170 B
210 B
Direct
100 E
120 E
150 E
170 E
210 E
Nominal
Capacity
(Litres)
per day
(kWh/24h)
100
120
150
170
210
100B
120B
B
B
100.0
125.0
48.0
52.0
Weight of
Weight
unit full
of unit
(Kg)
(Kg)
100
125
25
120
147
27
150
181
31
170
204
34
210
257
47
100
124
24
120
146
26
150
179
29
170
201
31
210
252
42
Standing Heat Loss
per year
(kWh/365d)
1.14
416
1.25
456
1.45
529
1.63
595
1.91
697
150B
170B
C
C
150.0
170.0
60.0
68.0
100E
120E
100.0
120.0
143
180
M
M
C
C
36.2
36.0
1418
1424
6.640
6.680
See Section 2 to 10
210B
C
210.0
80.0
Megalife
150E
170E
150.0
170.0
210.0
234
265
L
L
C
C
37.3
37.1
2741
2759
12.730
12.840
20.300
60°C
210E
332
XL
C
38.1
4395