Connecting a 9 kg LPG Cylinder
A Quick Disconnect (QDC) gas connection is provided with the hose and regulator.
Step 1. Place the gas cylinder onto a supporting base.
Step 2. Fasten regulator and hose assembly to cylinder valve outlet. Tighten firmly. When
connecting the hose and regulator assembly to the gas cylinder, take care to avoid
unnecessary twisting of the flexible hose. DO NOT over tighten connection.
Step 3. Open the gas cylinder valve one full turn to allow the gas to flow.
Step 4. Leak test all accessible connections thoroughly using a soapy water solution (1 part liquid
detergent and 4 parts water) prior to using the appliance. Bubbles will appear if connections
are not properly sealed. Tighten or rectify as necessary and retest.
Step 5. Refer to page 6 for full instructions.
Fixed Universal LPG and NG Connections
Fixed Universal LPG
connection
Natural Gas
Installation and connections for fixed NG and Universal LPG connections
must be completed by a certified gas fitter.
WARNING
The Stainless Steel flexi pipe is to be drawn through the base of the unit.
Ensure it is bent evenly and not kinked. See "Gas positioning diagram" on
CAUTION
page 21 for dimensions and positioning of the gas line opening.
Rinnai Australia

GAS CONNECTION

A 3/8" BSP fixed connection is also supplied with this unit.
This connection is for installations connected to a permanent fixed
Universal LPG connection (that supplies gas to other appliances in the
premises).
In order to connect to NG a conversion kit is required. This can be
purchased as an accessory item available from Rinnai.