Rinnai 4500 Owner's Operation And Installation Manual
Rinnai 4500 Owner's Operation And Installation Manual

Rinnai 4500 Owner's Operation And Installation Manual

4500 series outdoor fireplace
Table of Contents

Advertisement

Available languages

Available languages

WARNING: Improper installation, adjustment, alteration, service or maintenance can cause
injury or property damage. Read the installation, operating, and maintenance
instructions thoroughly before installing or servicing this equipment.
WARNING: For Outdoor Use Only
Owner's Operation and Installation Manual for the
Rinnai Outdoor Fireplace
4500 Series
WARNING: If the information in these instructions is not
followed exactly, a fire or explosion may result causing
property damage, personal injury or death.
- Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in
your building.
Immediately call your gas supplier from a neighbor's phone.
Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the fire
department.
- Installation and service must be performed by a qualified
installer, service agency or the gas supplier.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
Table of Contents ........... 2
Safety Information .......... 2
Parts List ........................ 21
Consumer Support ......... 26
French Version ............... 28

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 4500 and is the answer not in the manual?

Questions and answers

Summary of Contents for Rinnai 4500

  • Page 1: Table Of Contents

    Owner’s Operation and Installation Manual for the Rinnai Outdoor Fireplace WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Read the installation, operating, and maintenance instructions thoroughly before installing or servicing this equipment. WARNING: For Outdoor Use Only —...
  • Page 2: Table Of Contents

    Installing Body Assembly in an Open 1-sided or 2-sided Installation ... 15-17 Installing Burn Media ... 18 Complete Gas Connection ... 19 Guidelines for Cladding and Finishes ... 20 Parts List ... 21-25 Consumer Support ... 26, 27 Rinnai Corporation ROF4500...
  • Page 3: Safety Behaviors And Practices

    • Any guard or other protective device removed for servicing the appliance must be replaced prior to operating the appliance. Rinnai Corporation ROF4500...
  • Page 4: Specifications

    Weight Burner Assembly: 44 lb (20 kg) Body Assembly: 66 lb (30 kg) Burner and Body Assembly: 110 lb (50 kg) Rinnai is continually updating and improving products. Therefore, specifications are subject to change without prior notice. Troubleshooting Problem No gas...
  • Page 5: Burner Dimensions

    18.50 in (470 mm) With Fascia and Doors Dimensions 47.44 in (1205 mm) 19.21 in (488 mm) for 1-sided Frame is 1.57 in (40 mm) wide, 0.67 in (17 mm) deep 19.88 in (505 mm) for 2-sided Rinnai Corporation ROF4500...
  • Page 6: Assembly Specifications

    Assembly Specifications Burner Assembly The major component of the Rinnai outdoor fireplace is the burner assembly. This consists of a tube burner with an open tray filled with pumice and stones. A SIT pilot burner is positioned along the tube burner to ensure positive lighting and is covered by a perforated guard to prevent the pumice from blocking the burner.
  • Page 7: Installation Applications

    [3] Door assembly attaches to the cabinet frame of the appliance, and so is only suitable for installations where a cabinet (or body assembly) has been installed. Sample Installations Open 1-Sided Open 2-Sided Cabinet (ROF4501) Cabinet (ROF4502) Optional Accessories Rinnai Corporation ROF4500 Non-combustible enclosed masonry...
  • Page 8: Operating Instructions

    Inspect the burner before each use of the appliance. Ensure that no debris such as leaves or other objects have entered or are on the appliance. If the burner is damaged, it must be replaced with a Rinnai authorized replacement burner prior to operating the appliance.
  • Page 9: Care And Maintenance

    The appliance should be inspected before use and at least annually by a qualified service technician. More frequent cleaning may be required. Regular servicing is not covered by Rinnai’s warranty. Maintenance Task Inspect gas control assembly Clean Pilot / Burner...
  • Page 10: Installation Instructions

    1/2 psi (3.5 kPa). Refer to the conversion manual for converting the appliance to use natural gas. Do not install this appliance indoors. ROF4500 Rinnai Corporation ROF4500 ROF4501 ROF4502...
  • Page 11: Lpg Cylinder Enclosure

    10 square inches (64.5 sq. cm). Minimum of 5” (12.7 cm) from floor to top of bottom opening Rinnai Corporation ROF4500 Minimum of 2” (5 cm) from floor bottom to ground level...
  • Page 12: Definition Of An Outdoor Area

    ⇒ at least 30% of the walled area is open and unrestricted. Example: The walled area above is 280 square feet. Therefore, the area of all the openings in these walls must total to at least 84 square feet. (0.3 x 280 = Rinnai Corporation ROF4500 open both ends...
  • Page 13: Clearances

    Side of appliance to side wall. From an openable window, door, or non-mechanical air inlet, or any other opening into a building, with the exception of sub-floor ventilation. For example, an air conditioning unit Rinnai Corporation ROF4500 Freestanding recommended...
  • Page 14: Installing Freestanding Unit Or Enclosed Masonry Applications

    Install Burn Media and Complete Gas Connection This is common to all installations. Refer to these sections in the manual. Gas supply opening 17.91 in (455 mm) 19.68 in (500 mm) Rinnai Corporation ROF4500 Freestanding recommended 1.38 in (35 mm) Suggested size for gas 3.15 in...
  • Page 15: Installing Body Assembly In An Open 1-Sided Or 2-Sided Installation

    Installing Body Assembly in an Open 1-Sided or 2-Sided Installation Steel framing options are available for the open 1-sided and open 2-sided installations. For ease of installation, Rinnai provides a steel frame as a kit. Refer to the separate detailed instructions for assembly of the steel frame.
  • Page 16 47.0 in (1195 mm) maximum bracket timber stud 48.3 in (1225 mm) minimum cabinet 46.5 in (1180 mm) minimum clearance 47.0 in (1195 mm) maximum bracket Rinnai Corporation ROF4500 19.7 in non combustible (500 mm) cladding minimum non combustible cladding 18.5 in...
  • Page 17: Sided Or 2-Sided Installation

    Using the 2 self tapping screws supplied, fasten through the underside of the lower frame into the lower mounting brackets. Install Burn Media and Complete Gas Connection This is common to all installations. Refer to these sections in the manual. Rinnai Corporation ROF4500...
  • Page 18: Installing Burn Media

    Layer 3 - Single Layer of 14 Pieces of Large Quartz Place the 14 pieces of large quartz stones on top of the small quartz. Do not stack the large stones on large stones. Rinnai Corporation ROF4500...
  • Page 19: Complete Gas Connection

    4 parts water) prior to using the appliance. No leaks are allowed. SIDE VIEW CAUTION Rinnai Corporation ROF4500 Locate the hose out of pathways where people may trip over it or in areas where the hose may be...
  • Page 20: Guidelines For Cladding And Finishes

    If you are installing a door assembly, a heat rated material such as calcium silicate board must be above the fire. Such materials require installation and sealing in accordance with the supplier specification. Rinnai accepts no responsibility for deterioration of cladding or finishes. Rinnai Corporation ROF4500 heat rated material capable of withstanding 302°...
  • Page 21: Parts List

    REGULATOR LPG REGULATOR ANTI TWIST BRKT REDUCING FLARE 3/8X1/2BF480608 PLUG 1/8 NPT INJECTOR BLOCK A+B+C 1/8NPT US LABEL GAS TYPE UNIVERSAL LPG WIRE LABEL RHFE DATA PLATE US INJECTOR 2.00mm LPG MAIN TUBE ASSY ROF4500 PILOT TUBE ASSY ROF 4500...
  • Page 22 11223 11271 11228 11229 11329 9006 9324 9065 11342 Rinnai Corporation ROF4500 Description PILOT COVER TOP PANEL PILOT COVER ASSEMBLY PANEL CONTROL COVER GRANITE 272X20mm GRANITE 192X111mm WEATHER SHIELD ASSY SCREW BUTTON SOCKET 304 M5X12 RIVET POP PLAIN 73 AS 5.3 STAINLESS SCREW M4X10 PAN PHIL ST.ST 304...
  • Page 23 TOP PANEL ASSY ROF4502 11235 PANEL BODY REAR RADIUS ROF4501 11236 TRANSPORT BRACKET 11238 BODY CORNER BRACKET 11267 FASCIA MOUNTING BRKT R2615 FRAME TRIM SS 40MM 11253 LOUVRE TOP 11214 TOP FLASHING R2629 HEADER KIT 11268 INSTALLATION SPACER BRKT Rinnai Corporation ROF4500...
  • Page 24 Item No. Quantity The complete assembly can be purchased as Kit R2615 Frame Trim SS. Parts List Part No. Description 11264 FASCIA TOP 11266 FASCIA BOTTOM 11265 FASCIA VERTICAL 9065 SCREW M4x10 PAN PHIL ST.ST 304 Rinnai Corporation ROF4500...
  • Page 25: Parts List

    Parts List Item No. Quantity Part No. 11335 11334 11336 Rinnai Corporation ROF4500 Description GLASS DOOR ASSY RIGHT ROF4500 GLASS DOOR ASSY LEFT ROF4500 DOOR SWING CATCH SET ROF4500...
  • Page 26: Warranty Information

    What will Rinnai do? Rinnai will repair any part or component that is defective in materials or workmanship as set forth as follows. All repair parts must be genuine Rinnai parts. All repairs or replacements must be performed by an individual or servicing company that has been authorized by Rinnai.
  • Page 27 Rinnai will replace the product with a comparable product at Rinnai’s discretion. If a component or product returned to Rinnai is found to be free of defects in material or workmanship, or damaged by improper installation or damaged during return shipping, the warranty claim may be denied.
  • Page 28: French Version

    Manuel de l'opération et de l'installation du propriétaire pour Rinnai Cheminée Extérieur L'installation inexacte, l'ajustement, le changement, le service ou AVERTISSEMENT: l'entretien peuvent causer des dommages ou des dégats matériels. Lisez l'installation, l'opération, et les instructions d'entretien complètement avant d'installer ou entretenir cet équipement.
  • Page 29: Informations Pour La Sécurité Du Consommateur Définitions De Sécurité

    1 ouvert a dégrossi ou 2 ont dégrossi installation ... 42-44 Installation des médias de brûlure ... 45 Accomplissez le raccordement de gaz ... 46 Directives pour le revêtement et les finitions ... 47 Support à la clientèle ... 48, 49 Rinnai Corporation ROF4500...
  • Page 30: Comportements Et Pratiques De Sécurité

    • N'importe quelle garde ou tout autre dispositif protecteur enlevé pour entretenir l'appareil doit être remplacée avant d'actionner l'appareil. • Échec de flamme : L'appareil s'arrêtera automatiquement si on s'éteint la flamme de brûleur. Rinnai Corporation ROF4500...
  • Page 31: Spécifications

    Assemblée de brûleur : 44 livres (20 kilogrammes) Assemblée de corps : 66 livres (30 kilogrammes) Brûleur et Assemblée de corps : 110 livres (50 kilogrammes) Rinnai est continuellement mettant à jour et améliorant des produits. Par conséquent, les caractéristiques sont sujettes au changement sans préavis. Dépannage Problème...
  • Page 32: Dimensions

    19.21 in (488 mm) for 1-sided Frame is 1.57 in (40 mm) wide, 0.67 in (17 mm) deep La vue est 15.7 (40) au loin, 0.67 (17) profondément 19.88 in (505 mm) for 2-sided 19.88 (505) pour 2 dégrossis Rinnai Corporation ROF4500...
  • Page 33: Caractéristiques D'assemblée

    Caractéristiques d'Assemblée Assemblée de brûleur Le composant principal de la cheminée extérieure de Rinnai est le brûleur. Ceci se compose d'un brûleur à tube avec un plateau ouvert rempli de rénovation et de pierres. Un brûleur de pilote de SIT est placé le long du brûleur à tube pour assurer l'éclairage positif et est couvert par une garde perforée pour...
  • Page 34: Applications D'installation

    [3] Les attaches de porte à l'armature de coffret de l'appareil, et est ainsi seulement appropriée aux installations où un coffret (ou le montage de corps) a été installé. Installations témoin 1 a dégrossi 2 dégrossis (ROF4501) (ROF4502) Accessoires facultatifs Rinnai Corporation ROF4500 Maçonnerie incluse non-combustible...
  • Page 35: Instructions D'utilisation

    Inspectez le tuyau d'offre de gaz avant chaque utilisation de l'appareil. S'il y a d'évidence de l'abrasion ou de l'usage, ou si le tuyau est endommagé, il doit être remplacé avec un tuyau autorisé par Rinnai de rechange avant d'actionner l'appareil.
  • Page 36: Entretien

    être directement exposés à la pluie. Une couverture de temps a été Inspection visuelle de flame La cheminée extérieure de Rinnai a un modèle distinct de flamme. Ceci devrait regarder la même chose chaque fois après une première période de préchauffage d'approximativement 30 minutes.
  • Page 37: Instructions D'installation

    égales à ou moins d'à 1/2 livre par pouce carré (kPa 3.5). Référez-vous au manuel de conversion pour convertir l'appareil pour employer le gaz naturel. N'installez pas cet appareil à l'intérieur. ROF4500 Rinnai Corporation ROF4500 ROF4501 ROF4502...
  • Page 38: Clôture De Cylindre De Lpg

    10 pouces carrés (64.5 carrés. centimètre). Minimum de 5 pouces (12.7 cen- timètres) du plancher jusqu'au dessus de l'ouverture inférieure Rinnai Corporation ROF4500 Minimum de 2 pouces (5 cen- timètres) du fond de plancher au niveau du sol...
  • Page 39: Définition D'un Secteur Extérieur

    Exemple : Le secteur muré ci-dessus est de 280 pieds carrés. Par conséquent, le secteur des toutes ouvertures dans des ces murs doit se monter au moins à 84 pieds carrés. (0.3 x 280 = 84) Rinnai Corporation ROF4500 ouvrez les deux open both extrémités...
  • Page 40: Espacements

    Côté d'appareil au mur latéral. D'une fenêtre ouvrable, une porte, ou une entrée d'air non mécanique, ou toute autre ouverture dans un bâtiment, excepté la ventilation de secondaire-plancher. Par exemple, un dispositif climatique Rinnai Corporation ROF4500 Libre Recommandé minimum de la terre...
  • Page 41: Installation De L'unité Indépendante Oumaçonnerie Incluse

    Installez les médias de brûlure et accomplissez le raccordement de gaz C'est commun à toutes les installations. Référez-vous à ces sections du manuel. Ouverture de fourniture de gaz 17.91 in (455 mm) 19.68 in (500 mm) Rinnai Corporation ROF4500 Libre Recommandé minimum de la terre 1.38 in (35 mm)
  • Page 42: L'installation Du Montage De Corps Dans Un 1 Ouvert A Dégrossi Ou 2 Ont Dégrossi Installation

    Les options encadrantes d'acier sont disponibles pour le 1 ouvert dégrossi et ouvrent 2 installations dégrossies. Pour la facilité de l'installation, Rinnai fournit une armature en acier comme kit. Référez-vous aux instructions détaillées séparées pour l'ensemble de l'armature en acier.
  • Page 43 48.3 in (1225 mm) minimum coffret 46.5 in (1180 mm) minimum clearance équerres 47.0 in (1195 mm) maximum bracket Rinnai Corporation ROF4500 revêtement non non combustible combustible cladding revêtement non non combustible combustible cladding cabinet 19.7 in...
  • Page 44 Installez les médias de brûlure et accomplissez le raccordement de gaz C'est commun à toutes les installations. Référez-vous à ces sections du manuel. support et attache M5 Rinnai Corporation ROF4500...
  • Page 45: Installation Des Médias De Brûlure

    N'empilez pas les grandes pierres sur de grandes pierres. L'installation appropriée des médias de brûlure est critique à l'opération correcte de cet appareil. Chaque couche doit être installée comme indiqué ci-dessous. Rinnai Corporation ROF4500...
  • Page 46: Accomplissez Le Raccordement De Gaz

    (détersif liquide de 1 part et 4 parts d'eau) avant d'employer l'appareil. On ne permet aucune fuite. ATTENTION VUE DE CÔTÉ Localisez le tuyau hors des voies où les gens peuvent se déclencher plus de l'ou dans les secteurs où le tuyau peut être accidentellement endommagé. Rinnai Corporation ROF4500...
  • Page 47: Directives Pour Le Revêtement Et Les Finitions

    être au-dessus du feu. De tels matériaux exigent l'installation et le cachetage selon les spécifications de fournisseur. Rinnai n'accepte aucune responsabilité de détérioration de revêtement ou finit. le matériel évalué par chaleur capable de résister à 302° F (150°...
  • Page 48: L'information De Garantie

    Quel est l’engagement de Rinnai ? Rinnai réparera toute partie ou composant défectueux du fait des matériaux ou de la main d’œuvre dans les conditions qui suivent. Toutes les pièces à réparer doivent être des pièces Rinnai d’origine; Toutes les réparations et tous les replacements doivent être effectués par un dépanneur individuel ou une société...
  • Page 49 Garantie limitée Le remplacement du produit ne peut être autorisé que par Rinnai. La société Rinnai ne permet à aucune personne ou société d’assumer pour elle toute obligation ou responsabilité relative au remplacement d’un produit. Si Rinnai détermine que la réparation d’un produit n’est pas possible, Rinnai le remplacera avec un produit comparable, à...
  • Page 50 Notes Rinnai Corporation ROF4500...
  • Page 51 Notes Rinnai Corporation ROF4500...
  • Page 52 • Zero-Clearance Installation • Available in Four Options of Fronts • Remotes and Fan Included • Gas Conversion Kit Available Hydronic Air Handler • Designed for Use with Rinnai Systems • Domestic Hot Water Priority • Optional Programmable Thermostat •...

This manual is also suitable for:

Rof4500Rof4501Rof4502

Table of Contents