Specifications - Rinnai ROF4500 Operation & Installation Manual

Luminaire outdoor gas fire
Table of Contents

Advertisement

Burner
Combustion Method
Data Plate
Gas Control
Gas Connection (ULPG)
Ignition System
Input
Pilot
Internal Piping
Pressure Test Point
Regulator
Safety Devices
Flue Gas Outlet
Weight
Pilot Injector
Main Injector
Test Point Pressure (High)
Test Point Pressure (Low)
Minimum Supply Pressure
Maximum Supply Pressure
Include Dimensions
With Fascia & Doors - mm
(fascia add 40 mm)
Rinnai Australia

SPECIFICATIONS

Open Fronted Radiant / Convector Rinnai Luminaire Outdoor Gas Fire
with manual control.
Comes in 3 designs:
• Freestanding table top unit
• Open One sided cabinet
• Open Two sided see-through unit
Gas Type: Universal LPG / NG
Suitability: This is a permanently fixed luminous effect appliance
outdoor areas only. Not to be used for cooking food preparation or food
warming.
304 stainless steel tube burner
Aerated bunsen type burner
Left hand side of burner under granite cover
Gas control valve consisting of an inlet connection, Piezo ignitor, thermocouple flame
failure and manual control knob.
The valve operating sequence is to turn the valve to the pilot position before lighting
the main burner. Only, when the pilot has established can the gas valve be turned to
high and low combustion settings.
9 kg ULPG Cylinder: Quick Disconnect (QDC)
'Rectus Type 21'
Intermittent pilot
ULPG: 45-25 MJ/h (High to Low)
®
SIT
single injector pilot assembly with fixed aeration and replaceable fixed pilot
injector for NG and ULPG. Pilot assembly also contains a pilot ignition electrode and
thermocouple for flame failure.
Burner is supplied through an aluminium pipe from the gas control to the burner
injector block. Pilot burner is supplied gas via aluminium pipe directly from the gas
control.
Incorporated into main burner injector block measuring burner pressure
Pressure regulator with exchangeable spring for NG
Light to Pilot and Flame Failure Safety Device (FFD)
Top Louvre discharge (Cabinet models only)
Burner Assembly: 20 kg
ULPG
# 35
1.90 mm
2.45 kPa
0.80 kPa
2.50 kPa
3.50 kPa
- 10 -
(with optional glass bi-fold doors)
(with optional glass bi-fold doors)
NG: 5/8" UNF flared connection to
NG Regulator
NG: 41-22 MJ/h (High to Low)
Body Assembly: 30 kg
# 62
3.60 mm
0.43 kPa
0.13 kPa
1.13 kPa
3.50 kPa
Rinnai Luminaire® Outdoor Gas Fire - Operation and Installation Manual
(Burner + Body: 50 kg)
NG