Installation
The Gas pressure must be set by an approved
gas fitter as shown on the table presented
on the next page or, alternatively, on the
appliance data plate:
Natural gas 1.0 kPa
ULPG 2.75 kPa
1. Loosen the screw in the test point until it is
free in its housing. The screw is retained in
this position.
Natural Gas
115
Gas Pressure Test Point
Page 14
2. Connect the hose from the pressure gauge.
3. Reassemble one of the large burners, turn
on the gas and manually light the burners.
4. Disconnect gauge and screw in the test
point screw.
NOTE // The Gas Regulator must be set with the
largest burner operating at maximum setting.
ULPG
95
Gas Pressure Test Point
Gas Hob User Manual