Gas Connection - Platinum AUPL-GF61SS User Manual

Table of Contents

Advertisement

Installation
ATTENTION // If the connection cable is
damaged, it must be replaced by a suitably
qualified electrician.
The supply cord has been fitted with a
10A three-pin plug and is designed for use
with alternating current according to the
indications on the rating label (data plate)
located underneath the cooktop.
Before actual connection make sure that:
The fuse and electrical system can withstand
the load required by the appliance.
The electrical supply system is equipped with
an efficient earth hook-up according to the
norms and regulations prescribed by law.
The plug and switch are easily accessible
after installation.
The wires in the mains lead are coloured in
accordance with the following code:
Green & Yellow - Earth
Blue - Neutral
Brown - Live
As the colours of the wires in the mains lead
of this appliance may not correspond with the
coloured markings identifying the terminals in
your plug, proceed as follows:
The green and yellow wire must be connected
to the terminal in the plug that is marked with
the letter E or by the earth symbol or coloured
green or green and yellow.
The blue wire must be connected to the
Gas Hob User Manual
terminal that is marked with the letter N or
coloured black.
The brown wire must be connected to the
terminal that is marked with the letter A or
coloured red.
NOTE // This appliance must be earthed.

Gas Connection

IMPORTANT // Gas connections should be
carried out by a suitably qualified and competent
person in strict accordance with the requirements
of AS 5601 (gas installations) and national and
local regulations.
This gas cooktop can be connected with a class
B or D flexible hose, which complies with AS/
NZS 1869 and must be certified. The min. inner Ø
must be 10 mm and the maximum length 1.2 m.
Make sure it does not touch moving parts of the
kitchen furniture, e.g. a drawer. Ensure the hose
assembly is not exposed to high temperatures
exceeding the maximum recommended by the
hose manufacturer, subjected to strain, kinking,
permanent deformation or damage by vermin.
This appliance is factory fitted with Natural
Gas Injectors and is also supplied with a ULPG
conversion kit. The conversion of the appliance
to be used with ULPG must be undertaken by
qualified personnel. Please refer to the 'Gas
Conversion – Natural Gas / ULPG' section.
A Pressure Test Point is provided on the gas
regulator (supplied for natural gas) or on the
test point adaptor (supplied for ULPG).
Page 13