Page 1
User Manual Gas Hobs AUPL-GF61SS AUPL-GWF61SS AUPL-GWF91SS IMPORTANT Please ensure that you read through this manual prior to installation and use. This user manual contains important information to ensure optimal performance and keep you safe. Please retain your proof of purchase, as this will be needed in the event that you require a warranty service.
Warning & Safety Instructions IMPORTANT // To avoid the risk of accidents and damage to the appliance, please read these instructions carefully before using it for the first time. They contain important notes on installation, safety, use and maintenance. To maintain the efficiency and safety of this •...
Product Specifications Model: AUPL-GF61SS Dimensions W590 x D500 x H90mm Bench Cut-out Dimensions W553 x D473mm Voltage / Frequency 220-240V~ / 50Hz Power Capacity 4 Burners Gas Burners 1 Rapid / 2 Semi-rapid / 1 Auxiliary Model: AUPL-GWF61SS Dimensions W590 x D500 x H90mm...
Operating Instructions IMPORTANT // To ensure best performance, avoid risk of damage or accident. Please read the operating instructions prior to first time use. This appliance is supplied with a spare data plate label. Please attach it to an adjacent surface for future reference if the labels on the base of the cooktop are not visible after installation.
Operating Instructions NOTE // When one of the control knobs is centre, so they should stay beneath the pan base activated, sparks are generated on all burners of for a best efficiency and a lower risk of injuries the cooktop simultaneously. and damages on pan handles.
Cleaning & Maintenance ATTENTION // Before cleaning your oven, or 2. Soak them in hot water with a small amount performing maintenance, turn the appliance off of washing detergent. and disconnect it from the power supply. Also 3. Softly scrub off any remaining pieces of allow the appliance to cool down before touching food.
Installation IMPORTANT // This unit must be installed by authorised personnel and used only in permanently ventilated rooms in accordance with the requirements of AS 5601 (gas installations), wiring code, manufacturer’s instructions, local and national authority and any other statutory regulations. Follow carefully the safety instructions and clearance requirements given below.
Page 11
300mm away from the gas inlet. AUPL-GWF61SS / AUPL-GF61SS - The Gas inlet (3) is located underneath the appliance towards the rear left hand side 100mm from the rear edge. The Electrical terminal (4) is also located underneath the appliance approximately in the centre of the rear edge.
Installation Installation Procedure 8. Connect the appliance to the gas supply (refer to the ‘Gas Connection’ section). 9. Secure the appliance by matching the 1. Make the benchtop cut-out for the cooktop screws with the correspondent screw holes in accordance with the diagrams previously in each bottom corner of the cooktop.
Installation ATTENTION // If the connection cable is terminal that is marked with the letter N or damaged, it must be replaced by a suitably coloured black. qualified electrician. • The brown wire must be connected to the terminal that is marked with the letter A or The supply cord has been fitted with a coloured red.
Page 14
Installation The Gas pressure must be set by an approved 2. Connect the hose from the pressure gauge. gas fitter as shown on the table presented 3. Reassemble one of the large burners, turn on the next page or, alternatively, on the on the gas and manually light the burners.
Page 15
Installation Natural Gas Universal LPG AUPL-GF61SS Inj. diam. (mm) MJ/h Gas pressure Inj. diam.(mm) MJ/h Gas pressure Rapid burner x 1 1.50 10.8 1.0kPa 0.88 10.8 2.75kPa Semi-rapid burner x 2 1.12 6.30 1.0kPa 0.68 6.30 2.75kPa Auxiliary burner x 1 0.83...
Page 16
Installation Gas Conversion – Natural Gas / ULPG Follow the operations below for each burner in order to adjust the minimum flame intensities: This appliance is factory fitted with Natural 1. Light the burner. Gas Injectors (burner nozzles) and is also supplied with a ULPG conversion kit.
Page 17
Installation NOTE // A full operational test and a test for possible leakages must be carried out by the installer before leaving. Check all burner flames are blue in colour, stable and completely ignite at both high and low flame settings with no appreciable yellow tipping, carbon deposition, lifting, floating lighting back or objectionable odour.
NSW 1755 1300 985 815 customercare@platinumappliances.com.au platinumappliances.com.au Platinum is committed to ongoing research to ensure all information in this user manual is correct at time of going to print. Dimensions should be used as reference only and actual dimensions should be taken form the phyical product only.