REMOTE WIRED CHILLED WATER HIGH WALL UNITS
CWM L: INFRARED CHILLED WATER HIGH WALL UNITS
GENERAL
PRODUCT
SELECTION
INSTALLATION
MAINTENANCE
OPTIONAL
CONTROLS
WIRING
DIAGRAMS
OPERATING
INSTRUCTIONS
CWM (L) KITS
FAULT FINDING
COMPONENT
IDENTIFICATION
TEV Ltd.,
Armytage Road, Brighouse,
West Yorkshire, HD6 1QF, UK.
Tel: +44 (0)1484 405600
Fax: +44 (0)1484 405620
Email: sales@quartz.co.uk
TECHNICAL MANUAL
Part numbers, dimensions and weights
Unit features/accessories
Optional control valves, valve positions
Optional electric heating
Airflows
Coil water volumes
Air throws
Hydraulic resistances
Sound power and pressure levels
Chilled water/low pressure hot water coil duties
CWM (L) unpacking
Removing the case
Pipework
Interconnecting wiring, fuses
Gravity drain
Fitting the case
Fitting filters
Check list
User maintenance
CWM wired remote controller (RCC 30)
CWM L infrared remote controller
CWM
CWM L
CWM remote wired controller
CWM L infrared remote controller
Electric heaters
5m high condensate pump
Programmable timer (for CWM)
Pipe thermostat (for 2 pipe heat/cool systems)
CWM (L) valve connections
Remote return air sensor (for RCC30 controller)
All models
Exploded view of chassis with component identification
Exploded view of case
-1-
2
2
3
3
3
3
4
4
4
5
8
8
9
10
10
11
11
11
12
13
14
15
15
13
16
18
20
22
23
24
25
25
26
27
97308102-04

Advertisement

Table of Contents
loading

Summary of Contents for Quartz CWM 55

  • Page 1 Remote return air sensor (for RCC30 controller) FAULT FINDING All models COMPONENT Exploded view of chassis with component identification IDENTIFICATION Exploded view of case TEV Ltd., Armytage Road, Brighouse, West Yorkshire, HD6 1QF, UK. Tel: +44 (0)1484 405600 Fax: +44 (0)1484 405620 Email: sales@quartz.co.uk 97308102-04...
  • Page 2 The 973 series consists of CWM chilled water high wall units using remote wired controllers and CWM L chilled water high wall units using infrared controllers. PART NUMBERS - CWM (L) INDOOR UNITS CWM 55 CWM 75 CWM 105 97300001...
  • Page 3: Valve Positions

    OPTIONAL CONTROL VALVES 2 port on/off valves or 4 port diverting valves are available as factory fitted options. (4 port modulating valves are also available - contact TEV Technical Sales Department). 2 pipe cool only systems require one valve per fan coil. 2 pipe heat/cool systems (supplied from a reverse cycle chiller, or chiller + boiler) require one valve: if using an auto changeover thermostat, they also need a means of signalling heating or cooling status of the flow eg a pipe thermostat (kit shown on page 23).
  • Page 4: Sound Power Levels

    AIR THROWS --o--o--O--O--O--o--o-- HYDRAULIC RESISTANCES --o--o--O--O--O--o--o-- SOUND POWER and SOUND PRESSURE LEVELS 973 SERIES CWM (L) ( speed 1 = lowest, 3 = highest) SOUND POWER LEVELS Frequency Hz SOUND PRESSURE LEVELS MODEL SPEED 36.8 39.1 38.8 34.4 31.7 43.4 45.8 45.1 39.6...
  • Page 5 WALL MOUNTED CHILLED WATER PERFORMANCE DATA (kW) CWM (L) 55 COOLING DUTIES Minimum Speed Medium Speed Maximum Speed Room Air On CW Temperature 0.17 m 0.19 m 0.28 m db °C wb °C IN °C OUT °C Total Sensible Total Sensible Total Sensible...
  • Page 6 WALL MOUNTED CHILLED WATER PERFORMANCE DATA (kW) CWM (L) 75 COOLING DUTIES Minimum Speed Medium Speed Maximum Speed Room Air On CW Temperature 0.24 m 0.31 m 0.37 m db °C wb °C IN °C OUT °C Total Sensible Total Sensible Total Sensible...
  • Page 7 WALL MOUNTED CHILLED WATER PERFORMANCE DATA (kW) CWM (L) 105 COOLING DUTIES Minimum Speed Medium Speed Maximum Speed Room Air On CW Temperature 0.25 m 0.34 m 0.49 m db °C wb °C IN °C OUT °C Total Sensible Total Sensible Total Sensible...
  • Page 8: Installation

    INSTALLATION HANGING RAIL FIXING THE HANGING RAIL HANGING THE UNIT CHASSIS...
  • Page 9 S = No Electric Heating / Sans Batterie Electrique / Ohne Elektroheizung H = + Electric Heaters / + Batterie Electrique / Mit Elektroheizung H = 1.3 kW (CWM 55) = 1.8 kW (CWM 75), = 2.3 kW (CWM 105) @ 230V...
  • Page 10: Pipework

    FITTING THE CASE FITTING THE FILTERS CWM L INSTALLATION CHECK LIST Page Checked Is the unit square and level with the ceiling ? Is the pipework correctly supported throughout its length ? Is the pipework insulated right up to the unit ? Have all pipework joints been carefully checked for leaks ? Is the fuse size correct ? Is the interconnecting wiring correct ?
  • Page 11 CWM (L) USER MAINTENANCE ISOLATE THE UNIT ELECTRICALLY BEFORE COMMENCING ANY MAINTENANCE WORK In order to maintain maximum efficiency of this unit, it is important that the filters behind the return air grilles are cleaned regularly. To remove filters: Clean the filters by washing in tepid water, vacuuming or by tapping gently outside the building. To replace filters: THE UNIT SHOULD ALWAYS BE USED WITH A FILTER.
  • Page 12 -12-...
  • Page 13 CWM L PCB CONFIGURATION The PCB is factory set for CWM L units. No reconfiguration is needed, with or without an electric heater. CWM L PCB (FACTORY CONFIGURED FOR CWM L UNITS: JUMPER JMODE NOT REQUIRED) --o--o--O--O--O--o--o-- OPTIONAL CWM L REMOTE CONTROLLER CWM L units use an electronic remote control (available separately, part number 55500309).
  • Page 14: Optional Accessories

    CWM WIRING DIAGRAM CWM L WIRING DIAGRAM OPTIONAL ACCESSORIES -14-...
  • Page 15 'L' INFRARED REMOTE CONTROL • The handset should be pointed towards the unit. • Two seconds after the last button press, the whole displayed programme is automatically transmitted. • The unit responds with 1 beep. The transmit symbol A flashes whilst transmission is taking place. •...
  • Page 16 Press the TIMER ON set ‘S’ button and step to the required ON time. Hold the button down for repeated stepping. Press the TIMER ON ‘C’ button to cancel the ON time. 8. Setting the OFF Time Press the TIMER OFF ‘S’ button and step to the required OFF time. Hold the button down for repeated stepping. Press the TIMER OFF ‘C’...
  • Page 17 ELECTRIC HEATER KIT Part No. CWM L Part No. 55600401 55600411 55600402 55600412 55600403 55600413 ITEM DESCRIPTION ITEM DESCRIPTION SUPPLIED IN KITS Coil/element/fuse assy Coil clip 55600402/403/412/413 No.8 screws Relay assy 55600401/402/403 Cable clamps No.6 screws 55600401/402/403 Cable ties Terminal 55600411/412/413 Jumper bar 55600411/412/413...
  • Page 18 3. WIRING CWM L a) Route the harness from the fuse along the back panel using the cable clamps, ensuring the harness is above the cabinet fixing brackets b) Remove and discard the violet wire between the pcb relay and terminal 7. Connect the black wire from the fuse assembly to the PCB relay, Route the blue wire alongside the existing harness and connect to terminal N on the terminal rail.
  • Page 19: Fitting The Kit

    5m HIGH CONDENSATE PUMP KIT FOR CWM (L) UNITS 55600420 ITEM DESCRIPTION Pump Assembly This kit is for use on all versions of CWM and CWM L units and is for condensate removal where a lift of up to 5m is required.
  • Page 20: Troubleshooting

    WIRING Locate the black, blue and red wires in the unit near the pump and remove the cover from the black and blue wires. Connect: (i) Black wire to terminal L on the pcb (ii) Blue wire to terminal N on the pcb The plastic cover over the pcb can be removed for convenience: retain the cable tie.
  • Page 21 PROGRAMMABLE TIMER KIT 52500151 This kit can be used to give ON/OFF switching of the mains voltage control circuits of CWM units where the total current does not exceed 3 Amps. ELECTRIC HEATER CURRENTS CANNOT BE SWITCHED DIRECTLY. It is not required for CWM L units which have built in timers. ITEM DESCRIPTION 7 Day Programmable Timer...
  • Page 22: Gravity Drain

    PIPE THERMOSTAT KIT 96200070 This kit is for fan coils on 2 pipe systems supplied from a reverse cycle chiller (or chiller + boiler) and fitted with an auto changeover thermostat, to enable a single valve to operate in both heating and cooling modes. It prevents the room thermostat calling for cooling and the valve being opened when the flow is hot water, and vice versa.
  • Page 23 INSTALLATION INSTRUCTION FOR CWM (L) VALVE CONNECTIONS PART DESCRIPTION ITEM DESCRIPTION 97300405 FFO 4 port valve CWM 55 (CW) Pipe assy. CW only 97300406 FFO 4 port valve CWM 75 (CW) Pipes assy LPHW only 97300407 FFO 4 port valve CWM 105 (CW)
  • Page 24: Fault Finding

    This instruction is also applicable to return air sensor spare 04000012S The sensor can be fitted to the return air inlet to an air conditioning unit to improve operation eg. if the wall thermostat is placed outside the space being conditioned, or if there is considerable stratification in a room with a high ceiling, where the wall thermostat would not measure a representative temperature.
  • Page 25 EXPLODED VIEW OF CWM (L) with COMPONENT IDENTIFICATION Back panel 16 LPHW pipes (bottom exit) 31 Motor Condensate pump PCB 17 LPHW pipes (top exit) 32 Fan support bracket Condensate pump bracket 18 4 port LPHW valve 33 IR receiver PCB (CWM L) Condensate pump 19 2 port LPHW valve 34 Blanking plate (CWM L)
  • Page 26: Exploded View Of Case

    EXPLODED VIEW OF CASE Cover ( L/H) Vertical air deflection vane Horizontal air deflector vane (lower) Cover (centre) Grille (R/H) 10 Horizontal air deflector vane (upper) Cover (R/H) Grille (centre) 11 Connecting rod Filter Grille (L/H) 12 Blank (CWM): IR lens (CWM L) -26-...

This manual is also suitable for:

Cwm 105Cwm 75Cwm l105Cwm l 55Cwm l 75

Table of Contents