Now push the Remineralization Cartridge into the canister clips (Fig. 16). The direction of the Remin-
eralization Cartridge is important. THE TEXT SHOULD NOT BE UPSIDE DOWN. The arrow on the filter
indicates the direction of water flow. Take an elbow adaptor from the Small Parts Bag and screw it into
the right side of the Remineralization Cartridge. Then take last elbow adaptor from the small parts bag
and screw it into the left side of the Cartridge (Fig 16) Remember to apply 4-7 wraps of Teflon tape.
1
Push 2 more canister clips onto the
Figure 16
R.O. Membrane housing and push the
Remineralization Cartridge into place
Attaching the
PUREPRO
Remineralization
Cartridge and its
adaptors
www.aquasafecanada.com
Take a 4 inch piece of blue tubing from
Figure 17
the Small Parts Bag and insert one end
of the 4 inch blue tube to the elbow
Attaching the
adaptor on the right side of the Remin-
Remineralization
eralization Cartridge and the other end
Cartridge to the
to the elbow adaptor on the right side
of the D.I. Canister (Fig. 17).
D.I. Canister
The Remineralization Cartridge makes
pH balanced alkaline water and
releases a perfect balance of miner-
als in the form of calcium, magnesium sodium and potassium ions that can be 100% absorbed by the
human body. Because of this the ppm of the water dispensed at your Aquasafe™ faucet will be higher
than that coming out of the D.I. Canister.

10.0 Installing the Final Polishing Filter

Push the two remaining canister clips (found in the Large Parts Bag) onto the R.O. Membrane housing
in preparation for the Final Polishing Filter (step 1, Fig 18). You can rotate the other canisters back out
of the way to make room.
Now push the Final Polishing Filter into the canister clips (step 1, Fig. 18). The direction of the Final Pol-
ishing Filter is important. THE TEXT SHOULD BE UPSIDE DOWN so that the arrow on the filter indicates
the direction of water flow. Take the male 'T' adaptor from the small parts bag and screw it into the
left side of the Final Polishing Filter . Then take the straight male adaptor from the Small Parts Bag and
screw it into the right side of the Final Polishing Filter . (step 2 & 3, Fig 18) Remember to apply 4-7
wraps of Teflon tape.
page 10 | Maximus II + Remineralization Installation Instructions 09/13 | www.aquasafecanada.com
Remineralization
D.I. Canister
rotated back
to make room
2
Make sure the protective white plugs have been
removed from both ends of the Remineralization
Cartridge and connect an elbow adaptor to the
left side of the Cartridge
elbow
PUREPRO
Remineralization
adaptor
www.aquasafecanada.com
Use the 4 inch piece of blue tubing to connect the
D.I. Canister and the Remineralization Cartridge as shown.
PUREPRO
Remineralization
elbow
adaptor
3
Connect the last
elbow adaptor
to the right side of the
Remineralization
Cartridge
( lters shown
side by side and
without canister
clips for clarity)