Resin Canister - How To Change The D.i. Resin Beads - Aquasafe Maximus II Installation Instructions Manual

Reverse osmosis system combo with remineralization
Hide thumbs Also See for Maximus II:
Table of Contents

Advertisement

D.I. Resin Canister - How to change the D.I. Resin Beads
In order to change the D.I. Resin of your 6oz D.I. Resin Canister, you will need to have on hand the re-
placement D.I. Resin beads. If you do not have the needed replacement D.I. Resin Beads, you can easily
and securely order a 24 oz bag from our store.
Figure 34
1
Replacing the D.I.
2
Resin Beads
to faucet
NOTE:
Back View -
hanging
bracket
not shown
for clarity
4
Allow the water to
drain from the
positioning the
canister vertically
over your sink or
7
8
9
This concludes the instruction for changing the D.I Resin canister of your Aquasafe™ Reverse Osmosis
System.
Depressurize your system (see Fig. 27)
Remove (see Fig 10) the blue tubing from
both ends of the D.I. Resin Canister.
P U R E
P R O
R e m i n e r a l i z a t i o n
canister by
the like.
When the new D.I. Resin has entirely lled the DI Canister, inspect the threads of the DI canister and remove any
resin beads which have found their way into the threads of the canister. Also rinse out the blue end cap with
water.
Tighten the blue end cap back into its place with reasonable force. You can now position the D.I. Resin Canister
back into its normal place on the Reverse Osmosis System by pushing the canister down onto its canister clips.
Reinsert the blue tubing into the elbows on both sides of the D.I. Resin Canister. Turn on the Manual Shut-O
Valve and Tank Top Valve to repressurize your system.
www.aquasafecanada.com | Maximus II + Remineralization Installation Instructions 09/13 | page 23
3
to tank
to saddle clamp/drain
feed water in
Manual
Shut-O Valve
in "OFF" position
5
Remove one of
the blue end
caps by turning
the blue end
cap counter
clockwise.
Now pull the D.I. Canister out of its canister clips
PUREPRO
Remineralization
P U R E
P R O
R e m i n e r a l i z a t i o n
Dispose of the old D.I. Resin
6
Beads and re ll the now
empty D.I. Resin canister with
the new D.I. Resin Beads.
Tap down lightly
NOTE: It is important to
pack the resin into the
canister tightly. To ensure
this, hold the canister
vertically (straight up and
down) and ll half way and
then tap the canister lightly
on a surface which will act
to compact the resin into
place. Fill to the top then
tap again. Top up any air
space left with resin.

Advertisement

Table of Contents
loading

Table of Contents