1
Push 2 more canister clips onto the
Figure 16
R.O. Membrane housing and push
Attaching the 3rd
the third D.I. Canister into place
D.I. Canister and
its adaptors
www.aquasafecanada.com
D.I. Canisters
rotated back
to make room
Next repeat the process in sequence
Figure 17
for the third D.I Canister (Fig. 16). You
can rotate the canisters on their clips
Connecting
to make room for this last one. Screw
the three D.I.
another elbow into the left side of the
Canisters
last D.I. Canister. Use the second piece
of 4 in blue tubing to connect this el-
bow with the unconnected one on the
second D.I. Canister (step 2, Fig. 16).
Then on the right side of the third D.I.
Canister, insert the last elbow from the
Small Parts Bag into the "OUTLET" side
of the third D.I Canister (step 3, Fig.
16). Remember to apply 4-7 wraps of
Teflon tape.

10.0 Installing the Final Polishing Filter

Push the two remaining canister clips (found in the Large Parts Bag) onto the R.O. Membrane housing
in preparation for the Final Polishing Filter (Fig 18). The space is limited for all three DI stages and the
Final Polishing filter, but they will all fit. The configuration that we found works best is to have the final
polishing filter mounted in front of all three DI resin Canisters.
Now push the Final Polishing Filter into the canister clips (Fig. 18). The direction of the Final Polishing
Filter is important. DO NOT HAVE THE TEXT UPSIDE DOWN. The arrow on the filter indicates the direc-
tion of water flow. Take the male "T" adaptor from the Small Parts Bag and screw it into the right side of
the Polishing Filter. Then take the straight male adaptor from the small parts bag and screw it into the
left side of the Polishing Filter. (Fig 18) Remember to apply 4-7 wraps of Teflon tape.
Take the last of the three 4 inch piece's of blue tubing from the Small Parts Bag and insert one end of
the 4 inch blue tube to the top of the "T" adapter and the other end to the Elbow adapter on the right
side of the third D.I. Canister. (Fig. 19).
page 10 | Maximus II Installation Instructions 05/13 | www.aquasafecanada.com
2
Connect another elbow to the left side
of the third D.I. Canister and connect it to
the second D.I. Canister using a 4 inch
length of blue tube
elbow
elbow
www.aquasafecanada.com
3
Connect the last
elbow to the
right side of the
third D.I. Canister
Use the 4 inch pieces of blue tubing to connect
the rst and second D.I. Canisters as shown
and the second and third
D.I. Canisters
( lters shown
side by side and
without canister
clips for clarity)
1
Push the last canister clips onto the
Figure 18
R.O. Membrane housing and push
the Final Polishing Filter into place
Attaching the
Final Polishing
Final Polishing Filter
Filter and its
adaptors
www.aquasafecanada.com
D.I. Canisters
rotated back
to make room
Figure 19
The Final Polishing Filter remineralizes
your water to ensure it has a full-bod-
Attaching the
ied taste. Because of this the ppm of
Final Polishing
the water dispensed at your Aquasafe
to the 3rd D.I.
faucet will be higher than that coming
Canister
out of the D.I. Canisters.

11.0 Prepare the R.O. Water Holding Tank

The R.O. Water Holding Tank has an air bladder and a water blad-
der inside it. The air bladder comes pre-set from the factory at 7
Figure 20
PSI for your convenience. CAUTION: Changes to the PSI of the
air bladder inside the R.O Water Holding tank may cause harmful
Attach the tank
back pressure which can result in the Auto Shut-Off Valve (ASV)
top valve to the
malfunctioning. As such, please do not attempt to adjust the air
R.O. Water
pressure of your R.O Water Holding tank.
Holding Tank
Please note: For your convenience, the R.O Water Holding tank
can stand up or lay horizontal to conserve space if necessary.
Screw the tank top valve found in your Small Parts Bag onto the
threads found on top of the R.O Water Holding Tank (Fig. 20).
Remember to apply 4-7 wraps of Teflon tape to the thread of
the tank itself.
PLEASE NOTE: The long length of blue tubing used to flush your
prefilters is the tubing you will use to hook up both the water
storage tank as well as the dedicated Reverse Osmosis faucet
that came with your system.
You will need to cut this length of blue tubing in two pieces accordingly. The length of tubing used to
hook up your kitchen faucet (which will be attached to the left side of the Polishing Filter) will prob-
www.aquasafecanada.com | Maximus II Installation Instructions 05/13 | page 11
2
Connect the straight male adaptor to the left side
of the Polishing Filter
straight
Final Polishing Filter
male 'T' adaptor
male adaptor
www.aquasafecanada.com
3
Connect the
male 'T' adaptor
to the right side of the
Polishing Filter
Use the 4 inch piece of blue tubing to connect the
3rd D.I. Canister and the Final Polishing Filter as shown.
3rd D.I. Canister
( lters shown
side by side and
without canister
Final Polishing Filter
clips for clarity)