ResMed S8 Escape II User Manual

ResMed S8 Escape II User Manual

Positive airway pressure device
Hide thumbs Also See for S8 Escape II:

Advertisement

S8 Escape™ II
POSITIVE AIRWAY PRESSURE DEVICE
User Guide
English
ResMed Ltd (Manufacturer) 1 Elizabeth Macarthur Drive Bella Vista NSW 2153 Australia • ResMed Corp (US
Designated Agent) 14040 Danielson Street Poway CA 92064-6857 USA • ResMed (UK) Ltd (EU Authorized
Representative) 96 Milton Park Abingdon Oxfordshire OX14 4RY UK • ResMed Offices Australia, Austria, Belgium,
Brazil, China, Finland, France, Germany, Greece, Hong Kong, India, Ireland, Italy, Japan, Malaysia, Mexico, Netherlands,
New Zealand, Norway, Portugal, Singapore, South Africa, Spain, Sweden, Switzerland, UK, USA (see www.resmed.com
for contact details).
Protected by patents: US 5199424, US 5522382, US 6705315. Other patents pending.
Protected by design registrations: AU 302180, AU 302181, AU 302182, AU 302183, AU 302184, AU 302185, AU 302186,
CN 200430121212.2, CN 200430121213.7 , CN 200430121211.8, CN 200430121214.1, CN 200430121215.6, CN
200430121216.0, CN 200430121217 .5, EP 269436, HK 0412901.9, JP 1257662, JP 1257663, JP 1266956, JP 1266957 , JP
1267270, JP 1267271, NZ 405614, NZ 406923, NZ 406924, NZ 406925, NZ 406926, NZ 406927 , NZ 406928, US
D544598, US D553228, US D557406, US D557407 , US D560795, US D561891, US D565160. Others pending.
S8, S8 Escape, ResScan, ResControl, ResLink and ResTraxx are trademarks of ResMed Ltd and Escape and
HumidAire are registered in U.S. Patent and Trademark Office.
© 2008 ResMed Ltd.
338613/1 08 07

Advertisement

Table of Contents
loading

Summary of Contents for ResMed S8 Escape II

  • Page 1 User Guide English ResMed Ltd (Manufacturer) 1 Elizabeth Macarthur Drive Bella Vista NSW 2153 Australia • ResMed Corp (US Designated Agent) 14040 Danielson Street Poway CA 92064-6857 USA • ResMed (UK) Ltd (EU Authorized Representative) 96 Milton Park Abingdon Oxfordshire OX14 4RY UK • ResMed Offices Australia, Austria, Belgium, Brazil, China, Finland, France, Germany, Greece, Hong Kong, India, Ireland, Italy, Japan, Malaysia, Mexico, Netherlands, New Zealand, Norway, Portugal, Singapore, South Africa, Spain, Sweden, Switzerland, UK, USA (see www.resmed.com...
  • Page 2: Table Of Contents

    Stop Treatment How to Use the Control Panel How to Change the Settings on your S8 Escape II Using the Data Card to Collect data ......8 Cleaning and Maintenance .
  • Page 3: Introduction

    The S8 Escape II CPAP system is intended for home and hospital use. Contraindications The S8 Escape II is not a life support device and may stop operating during power failure or certain fault conditions. It should not be used by patients who are dependent on continuous therapy.
  • Page 4: The S8 Escape Ii System

    Products page under Service & Support. ResScan Data Card The ResScan Data Card may be used with the S8 Escape II either to help your clinician to monitor your treatment or to provide you with updates to your device...
  • Page 5: Using The S8 Escape Ii

    • Set Up the S8 Escape II Connect the power cord to the socket at the rear of the S8 Escape II. Plug the other end of the power cord into the power outlet. Connect one end of the air tubing firmly onto the air outlet.
  • Page 6: Start Treatment

    Fit your mask as described in the mask user instructions. WARNING A mask should not be used unless the S8 Escape II device is turned on and operating properly. When ramping begins the LCD will display the word “RAMPING“, with the current pressure indicated as dashes.
  • Page 7 The S8 Escape II keypad has the following keys: Function Start/Stop Starts or stops treatment. Allows you to increase settings options and scroll through the S8 Escape II menu. Down Allows you to decrease settings options and scroll through the S8 Escape II menu.
  • Page 8: How To Change The Settings On Your S8 Escape Ii

    How to Change the Settings on your S8 Escape II You can change settings (such as Ramp Time) on the S8 Escape II by using the keypad and LCD. When the S8 Escape II is in standby mode you can display a series of screens (a menu) on the LCD screen in order to view and change the settings for a particular function.
  • Page 9 (Apply) to save the new language. Messages on the S8 Escape II LCD Your clinician may have set your S8 Escape II to remind you about important events, such as when to replace your mask, when to insert your Data Card (if your device is Data Card enabled) and so on.
  • Page 10: Using The Data Card To Collect Data

    Card to copy data from your S8 Escape II, and to return the card to them. The Data Card will be provided in a protective folder. Data that is copied to a Data Card is still stored and available on the S8 Escape II. Copy data onto the Data Card 1.
  • Page 11: Daily

    4. Before next use, reconnect the air tubing to the air outlet and mask. Monthly 1. Clean the exterior of the S8 Escape II with a damp cloth and mild liquid soap. 2. Check the air filter for holes and blockage by dirt or dust. Replace it every six months, or more often in a dusty environment (see “Replacing the Air Filter”...
  • Page 12: Servicing

    Servicing CAUTION Do not attempt to open the S8 Escape II case. There are no user • serviceable parts inside. Inspection and repair should only be performed by an authorised agent. • Under no circumstances should you attempt to service or repair the S8 Escape II yourself.
  • Page 13: Troubleshooting

    Please consult the medical services department of your carrier if you intend to use your S8 Escape II on an aircraft. The S8 Escape II complies with US FCC Part 15, Class B requirements.
  • Page 14 Insufficient air delivered from S8 Escape II Ramp Time is in use. Wait for air pressure to build up or change ramp time. Air filter is dirty. Replace air filter. Air tubing is kinked or Straighten or replace tubing. punctured.
  • Page 15: Technical Specifications

    Weight 1.3 kg • Power Supply Input range for S8 Escape II with HumidAire 4i:100–240V, 50/ 60Hz; 110V, 400Hz; 2.5A < 140VA (110W) (maximum power consumption). Instantaneous peak power consumption <340VA. • Refer to the DC-12 converter instructions for DC ratings. Only use the ResMed DC-12 converter for DC input.
  • Page 16: General Warnings And Cautions

    ResMed, or by a physician or respiratory therapist. A mask should not be used unless the S8 Escape II device is turned on and operating properly. The vent hole or holes associated with the mask should never be blocked.
  • Page 17 The S8 Escape II can be set to deliver pressures up to 20 cm H O. In the • unlikely event of certain fault conditions, pressures up to 30 cm H O are possible. If oxygen is used with this device, the oxygen flow must be turned off when •...
  • Page 18: Limited Warranty

    ResMed shall not be responsible for any incidental or consequential damages claimed to have occurred as a result of the sale, installation or use of any ResMed product. Some regions or states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation may not apply to you.