General; Performance Data; General Data - IDEAL imax plus F80 Installation And Servicing

Table of Contents

Advertisement

Table 1 Performance Data
Boiler
Boiler output
(non-condensing)
Mean 70ºC
Boiler output
(condensing)
Mean 40ºC
Boiler Input
Max Rate
Boiler Input
Min Rate
Maximum Gas Rate
Approx. flue gas
@ max. rate
volume (@80ºC) i.e. non-condensing ft
Max. Flue Resistance
Flue Gas CO
@ Max Rate
2
@ Min. Rate
NOx with O
= 0%
2
Part load efficiency
(Gross)
Table 2 General Data
Boiler
Gas supply
Gas supply connection
Flow connection
Return connection
Hydraulic Resistance @ 11Cº
Hydraulic Resistance @ 20Cº
Max Press (sealed system)
Maximum Static Head
Boiler Electricity Supply
Boiler Fuse Rating
Power Consumption (boiler only)
Air Inlet
Flue Size dia
Condensate drain
Water Content
Boiler dry weight (unpacked)
* Electricity supply and Fuse rating for pumps etc. refer to manufacturer's instructions.
Note.
Natural gas consumption is calculated using a calorific value of
37.8MJ/m
3
(1038Btu/ft
3
) gross or 34 MJ/m
15ºC and 1013.25 mbar.
a . For l/s divide the gross heat input (kW) by the gross C.V. of
the gas (MJ/m
3
)
3
b. For ft/h
divide the gross heat input (Btu/h) by the gross C.V.
of the gas (Btu/ft
3
).
HEALTH & SAFETY DOCUMENT NO. 635
The electricity at work regulations, 1989. The manufacturer's
notes must NOT be taken, in any way, as overriding statutory
obligations.
CAUTION.
To avoid the possibility of injury during the installation, servicing or cleaning of
this appliance, care should be taken when handling edges of sheet steel components.
2
F80
Max
kW
77.3
Btu/h
263,750
Min
kW
11.6
Btu/h
39,600
Max
kW
83.9
Btu/h
286,300
Min
kW
13.0
Btu/h
44,350
Nett
kW
80
Btu/h
272,950
Gross
kW
88.8
Btu/h
303,000
Nett
kW
12
Btu/h
40,950
Gross
kW
13.3
Btu/h
45,400
m
3
/h
8.42
3
ft
/h
297
3
m
/h
130
3
/h
4,590
Pa
100
%
9.0 - 9.2
%
8.8 - 9.0
mg/kWh
<62
ppm
<35
%
97.7
F80
R (in. BSP)
1
1
/
2
R (in. BSP)
2
R (in. BSP)
2
mbar
280
mbar
80
bar (psi)
6 (87)
m (ft)
61 (200)
W
175
m m
150
m m
150
m m
40
l (gal)
10.1 (2.2)
kg (lb)
153 (337)
3
(910 Btu/ft
3
) nett at

GENERAL

F120
F160
116
154.6
395,800
545,950
11.6
11.6
39,600
39,600
125.9
167.8
429,600
572,550
13.0
13.0
44,350
44,350
120
160
409,450
545,950
133.2
177.6
454,500
606,000
12
12
40,950
40,950
13.3
13.3
45,400
45,400
12.63
16.83
446
594
196
261
6,920
9,220
100
100
9.0 - 9.2
9.0 - 9.2
8.8 - 9.0
8.8 - 9.0
<62
<62
<35
<35
97.7
97.7
F120
F160
2H - G20 - 20 mbar
1
1
/
1
1
/
2
2
2
2
2
2
350
450
100
130
6 (87)
6 (87)
61 (200)
61 (200)
230V - 50Hz
External: 3A* internal: 1.6AT & 2AF
250
325
150
150
150
150
40
40
14.2 (3.1)
18.3 (4.0)
182 (401)
223 (492)
IMPORTANT. These appliances are CE certified for safety and
performance. It is, therefore, important that no external control
devices, e.g. flue dampers, economisers etc., are directly
connected to these appliances unless covered by these
Installation and Servicing Instructions or as otherwise
recommended by Caradon Ideal Limited in writing. If in doubt
please enquire.
Any direct connection of a control device not approved by
Caradon Ideal Limited could invalidate the certification and the
normal appliance warranty. It could also infringe the Gas Safety
Regulations and the above regulations.
F200
F240
193.2
231.8
659,250
818,900
11.6
11.6
39,600
39,600
209.8
251.8
715,850
859,200
13.0
13.0
44,350
44,350
200
240
682,450
818,900
222.0
266.4
757,500
909,000
12
12
40,950
40,950
13.3
13.3
45,400
45,400
21.04
25.26
743
892
326
392
11,510
13,840
100
100
9.0 - 9.2
9.0 - 9.2
8.8 - 9.0
8.8 - 9.0
<62
<62
<35
<35
97.7
97.7
F200
F240
1
1
/
1
1
/
2
2
2
2
2
2
550
720
180
225
6 (87)
6 (87)
61 (200)
61 (200)
400
475
150
150
200
200
40
40
22.4 (4.9)
26.5 (5.8)
261 (575)
301 (664)
-
Installation & Servicing
F280
270.5
923,000
11.6
39,600
293.7
1,002,150
13.0
44,350
280
955,400
310.8
1,060,500
12
40,950
13.3
45,400
29.46
1040
457
16,140
100
9.0 - 9.2
8.8 - 9.0
<62
<35
97.7
F280
1
1
/
2
2
2
870
275
6 (87)
61 (200)
550
150
200
40
30.6 (6.7)
345 (761)