H S M 2 H O S T I n s t a l l a t i o n M a n u a l
3.2.5 [804][810] Wireless Options
To program wireless options:
1.
Enter Installer Programming section [804][810].
2.
Select one of the following options by scrolling or entering the hotkey:
Table 3-6: Wireless Options
01 RF Delinquency
02 Wireless Supervisory/
RF Jam Alarm
03 Wireless Tamper
04 200s Fire Supervision
3.
Press [*] to accept the selection and [#] to exit.
3.2.6 [804][841] Motion Cameras
To program motion cameras:
1.
Enter Installer Programming section [804][841].
2.
Select one of the following options by scrolling or entering the hotkey:
Table 3-7: Motion Camera Options
[001] Visual Verification
[002] View Time Window
[003] View Other Alarms
3.2.7 [804][901]-[905] Delete Wireless Devices
To delete wireless devices:
1.
Enter Installer Programming section [804] then select one of the following sub-sections:
Table 3-8: Module Label Sub-Sections
Sub-Section
[901]
Delete wireless zone devices
[902]
Delete wireless key
[903]
Delete sirens
[904]
Delete repeaters
[905]
Delete keypads
2.
Select a device to delete using the scroll keys or go directly to a specific device by entering a hotkey.
3.
Press [*] to delete or [#] to exit.
3.2.8 [804][921]-[925] Replace Wireless Devices
Use this option to replace a faulty device enrolled on the system with another device of the same type while maintaining the configuration of the
original. The faulty device does not need to be deleted.
To replace a wireless device:
1.
Enter Installer Programming section [804] then select one of the following sub-sections:
Table 3-9: Replace Device Sub-Sections
Sub-Section
[921]
Replace wireless zone devices
[922]
Replace wireless keys
[923]
Replace sirens
[924]
Replace repeater
[925]
Replace keypad
On: the system cannot be armed if a wireless supervisory trouble exists. An RF delinquency trouble is generated.
Off: wireless supervisory troubles do not prevent arming.
On: if a supervisory or jamming trouble occurs during Away arming, the siren activates and the event is
logged and reported.
Off: supervisory or RF jam troubles during Away arming do not activate the siren or get logged and reported.
On: module tampers are logged and reported.
Off: module tampers are not logged or reported.
On: fire devices are supervised every 200 seconds. If the device fails to report within this window, a supervi-
sion trouble is generated.
Off: fire devices follow the supervision window programmed in section 802, up to a maximum of 18 hours. The
supervisory window can be programmed with a higher value, but detectors still go into fault after 18 hours.
On: Alarms trigger image capture from PIR Cameras
Off: Alarms do not trigger image capture from PIR Cameras
01 Alarm + 5 Minutes
02 Alarm + 15 minutes
03 Alarm + 1 Hour
01 Fire key enabled/disabled
02 Duress enabled/disabled
03 Medical key enabled/disabled
04 Panic key enabled/disabled
Description
Description
W i r e l e s s D e v i c e S e t u p a n d P r o g r a m m i n g
9