AC
POWER
WARNING! For protection from electric shock, the fixture must be grounded (earthed). The AC mains
supply shall be fitted with a fuse or circuit breaker and ground-fault protection.

Power supply

The MAC 2000 Wash is shipped configured for 200 - 250 V at 50/60 Hz, but can be manually switched to
accept either 100 - 130 V or 200 - 250 V power supplies.
Switching to match local power supply voltage
1 Ensure the fixture is not connected to power.
Lock the head vertically
2 Remove the four screws in the corners of the
display-side top panel and lift the panel clear.
Avoid strain on the panel ground (earth) cable
by supporting the panel.
3 The power supply switch is located in the
base unit at the end furthest from the display
(see Figure 5).
4 Set the switch to 115 V for a 100 - 130 V AC
power supply. Set the switch to 230 V for a
200 - 250 V AC power supply.
5 Replace the panel and screws. Remember to
unlock the head before using the fixture.
8
Figure 4: Removing display side top panel
115
230
MAC 2000 Wash
Figure 5: Power supply switch