NTRODUCTION Thank you for selecting the Martin CX-4. The CX-4 is an automated profile spotlight designed for a 150 watt discharge source. It provides colors, gobos, 5 beam angles, a frost effect, continuous dimming, adjustable focus, and multiple control options.
Page 5
U N P A C K I N G The packing material is carefully designed to protect the fixture during shipment - always use it to transport the fixture. The CX-4 comes with: • Philips CDM-SA/T 150W discharge lamp • 3-meter, 3-wire IEC power cable •...
GE Arcstream 150 77 Lm/W 4000 K 6000 h The CX-4 can be modified with a different lamp socket that allows use of the following lamps: • Martin HTI 150 W, 2000 h • OSRAM HTI 150 W, 750 h •...
Page 7
4 If the light is brighter around the edge than it is in the center, or if light output is low, turn the screws counterclockwise 1/4-turn at a time until the light is evenly distributed and there is not further improvement. CX-4 user manual Lamp...
POWER CONNECTION The CX-4 power supply must be wired to the voltage and frequency setting that most closely matches the local AC supply. The factory setting is shown on the serial number label. Warning! For protection from fire and electric shock, the fixture must be grounded (earthed).
Page 9
2 3 4 5 6 7 8 2 3 4 5 6 7 8 orange orange orange orange blue blue white white black black brown brown 2 3 4 5 6 7 8 orange orange blue white black brown CX-4 user manual AC power connection...
Page 10
4 Tug lightly on the black wire to make sure that it is connected securely. 5 Replace the top cover. 50 Hz 60 Hz black black brown brown AC power connection CX-4 user manual...
NSTALLATION The CX-4 can be fastened directly to a suitable surface or hung with a rigging clamp bolted to its adjustable mounting bracket. Do not lay the fixture flat on its mounting bracket arms or position it so that there is less than 10 cm (4 in.) clearance around the fan and air vents.
3 Terminate the link by inserting a male termination plug (P/N 91613017) into the data output of the last fixture. A termination plug is simply an XLR connector with a 120 ohm, 0.25 W resistor soldered across pins 2 and 3. Data connection CX-4 user manual...
To connect units for master / operati on 1 Connect the output of one CX-4 to the input of the next CX-4. 2 Connect additional CX-4s output to input. Up to 32 may be connected. 3 Terminate the link on both ends by inserting a female termination plug (P/N 91613018) into the data input of the first fixture and a male termination plug into the data output of the last fixture.
Page 14
The DIP-switch 10 setting takes effect only after the fixture has been turned off and on. Fixture Option Setting (0 = OFF, 1 = ON) auto trigger single or music trigger master slow change random color random effect client inverted color inverted effect Stand-alone operation CX-4 user manual...
MC-1 OPERATION The CX-4 is fully compatible with the Martin MC-1 Controller. See the MC-1 user manual for additional information. M C - 1 M O D E S E T T I N G S DIP-switch pin 10 must be set to OFF to enable MC-1 mode operation. Changes to the setting take effect after the fixture has been turned off and on.
OPERATION D M X M O D E S The CX-4 has 2 DMX modes to choose from: a 1-channel mode that provides control of the built-in stand-alone features, and a 6-channel mode that provides full control of all effects.
Page 18
5 to the “tracking” speed (0 percent). Channel 6 controls the speed of the color and effect wheels. If your controller has cross-faders, and you use them, then set channel 6 to fast (0 percent). DMX operation CX-4 user manual...
ASIC SERVICE The CX-4 requires simple routine maintenance. The maintenance schedule depends heavily on the operating environment; please consult a Martin service technician for recommendations. Any service procedure not described here should be referred to a qualified technician. Important! Excessive dust, grease, and smoke fluid buildup degrades performance and causes overheating and damage to the fixture that is not covered by the warranty.
Page 20
R E P L A C I N G F U S E S The CX-4 has 2 fuses. The main fuse holder is built in to the mains input socket. The secondary fuse is located on the printed circuit board.
No light. Lamp missing or blown lamp. Fixture is too hot. Allow fixture to cool. Lamp cuts out intermittently or The transformer setting does not burns out too quickly. Check AC setting. match local AC voltage. CX-4 user manual Troubleshooting...