Display Messages - Martin Professional MAC 2000 Wash User Manual

Table of Contents

Advertisement

D
ISPLAY MESSAGES
Message
RST ( Reset)
SR ST (Serial reset)
HO ME
OP EN
LE RR (Lamp error)
ME RR (Memory error)
Sh ER (Short error)
bT ER (Base temperature error)
HT ER (Head temperature error)
Fb EP (Feedback error pan)
Fb ET (Feedback error tilt)
Fb ER (Feedback error pan/tilt)
PA ER (Pan time-out)
TI ER (Tilt time-out)
CY ER (Cyan time-out)
MA ER (Magenta time-out)
YE ER (Yellow time-out)
CT ER (CTC time-out)
C1 ER (Color wheel 1)
C2 ER (Color wheel 2/Dimmer
wheel time-out)
ZO ER (Zoom time-out)
RB ER
S3 SC
S4 SC
S5 SC
S6 SC
S7 SC
S8 SC
S9 SC
S1 0S
S1 1S
S1 2S
RA ME
OP ER
Appears when...
... the fixture is indexing effects at
startup.
... the fixture has received a reset
command from the controller.
... the effects have been indexed and are
moving to their default positions.
...the lamp access cover is not fully
closed.
... the lamp does not ignite within 10
minutes of receiving the 'Lamp ON'
command. Likely reasons are a missing
or defective lamp, or insufficient AC
voltage.
...the EEPROM memory cannot be read.
... the fixture detects the lamp is ON but
no 'Lamp ON' command has been
received. This can occur if the lamp relay
is stuck or if the lamp-power feedback
circuit fails. The fixture may be operated
but remote lamp on/off may be affected.
... there is a fault with the temperature
sensor in the base or head.
...pan (FbEp), tilt (FbET) or both (FbER)
feedback circuits are malfunctioning. It is
still possible to operate the fixture,
although it switches to "safe" mode with
reduced maximum speed, thus
preventing the fixture from losing track of
its home position (losing step).
...the electric indexing circuit is
malfunctioning. The fixture will, after the
time-out, establish a mechanical stop,
and continue to work normally.
...the barndoor rotation mechanism is
malfunctioning.
...an effect does not move away from the
index position under reset, a sensor or
micro-switch circuit is shorted, or a
micro-switch is stuck or connected
incorrectly.
...there is an onboard RAM memory
error.
...there is an onboard programming
error.
Table 2: Display messages

Display messages

What to do
Wait for reset to complete.
Wait for reset to complete. Set
PERS/dRES to OFF to prevent
accidental reset commands.
Wait a few moments.
Verify that the lamp access cover is
locked in place.
Check the lamp. Check that the
voltage and frequency settings match
the local supply.
Contact Martin service personnel for
assistance.
Contact Martin service personnel for
assistance.
Contact Martin service personnel for
assistance.
Contact Martin service personnel for
assistance.
Reset fixture. Contact Martin service
personnel if problem continues.
Reset fixture. Contact Martin service
personnel if problem continues.
Contact Martin service personnel for
assistance.
Contact Martin service personnel for
assistance.
Contact Martin service personnel for
assistance.