SECTION 10 – GENERATOR POWER GUIDELINES
10-1. Selecting Equipment

0-2. Grounding Generator To Truck Or Trailer Frame

Electrically bond generator
frame to vehicle frame by
metal-to-metal contact.
1
2
3
OR
1
2
GND/PE
1
2
3
Y Do not use 2-prong plug un-
Be sure equipment
has this symbol
and/or wording.
gen_pwr 6/02 – Ref. ST-159 730 / ST-800 577
Y Always ground generator
1
2
3
Connect cable from equipment
ground terminal to metal vehicle
frame. Use #10 AWG or larger
insulated copper wire.
Y If unit does not have GFCI re-
3
Generator Power Receptacles
– Neutral Bonded To Frame
3-Prong Plug From Case
Grounded Equipment
2-Prong Plug From Double
Insulated Equipment
less equipment is double in-
sulated.
frame to vehicle frame to pre-
vent electric shock and static
electricity hazards.
Equipment Grounding
Terminal (On Front Panel)
Grounding Cable (Not
Supplied)
Metal Vehicle Frame
ceptacles, use GFCI-pro-
tected extension cord.