4-16. Connecting To Miller Welder/Generator With A Three-Phase AC Power Plant

Three-Phase Power Connection
Remove plug
before inserting
leads. Reinstall
bushing.
4
5
6
8
7
Tools Needed:
OM-242 880 Page 22
.
A complete Parts List is available at www.MillerWelds.com
!
Close panel opening
if no connections are
made to generator.
Rear Of Panel
91
92
93
240V
120V
1-Phase
120V
240V
3-Phase
240V
240V
Single
Three
AC
Phase
Phase
Output
1
3
Volts
120/240
240
Amps
50
48
KVA/KW
12
20
Frequency
60 Hz
Engine Speed
1850 RPM
Lead 42 connects to GROUND stud on
front of unit.
Jumper 42 is connected to 90 at factory.
3
2
1
11
9
10
!
Close
panel
opening if no
connections
are made to
generator.
93
91
90
92
Three-Phase Generator Power
!
Stop engine.
!
Power and weld outputs are
live at the same time. Discon-
nect
or
insulate
unused
cables.
.
Have qualified person install ac-
cording to circuit diagram and
Generator Power Guidelines
(see generator Owner's Manual).
Remove generator power panel
mounting screws. Tilt panel forward.
1
Circuit Breaker CB7
2
Lead 93
3
Lead 92
4
Lead 91
5
Lead 42 (Circuit Grounding
Lead)
6
Lead 90 (Neutral)
7
Isolated Neutral Terminal
8
Jumper Lead 42
9
Grounding Terminal
Jumper 42 is connected to lead 90 at
factory. Jumper 42 may be discon-
nected from neutral to meet applica-
ble electrical codes.
Lead 42 connects to front panel
Ground stud.
10 Power Cord
11 Circuit Breaker CB7 User
Terminals
.
Circuit breaker CB7 protects
single-phase receptacle RC5
and the load wires from overload.
If CB7 opens, all three-phase
generator output stops and the
receptacle does not work.
Connect user-supplied ring lug to
green (ground) lead. Connect ring
lug on end of green (ground) lead
to grounding terminal (9).
Connect black, white, and red
leads to circuit breaker CB7 user
terminals (11).
Reinstall power panel.
Ref. 197 399 / 802 332-B