5-6. Activating The Dry Charge Battery (If Applicable)

1
2
5 A For 30 Minutes
OR
30 A For 12 Minutes
OM-495 Page 28
4
3
6
+
Return To Table Of Contents
Remove battery from unit.
1
2
5
3
4
5
Fill each cell with electrolyte to
bottom of well (maximum).
Y Do not overfill battery cells.
Wait ten minutes and check electro-
lyte level. If necessary, add electro-
lyte to raise to proper level. Reins-
tall vent caps.
6
Y Read and follow all instruc-
Charge battery for 12 minutes at 30
amperes or 30 minutes at 5 am-
peres. Disconnect charging cables
and install battery.
.
Eye Protection − Safety
Glasses Or Face Shield
Rubber Gloves
Vent Caps
Sulfuric Acid Electrolyte
(1.265 Specific Gravity)
Well
Battery Charger
tions supplied with battery
charger.
When electrolyte is low, add
only distilled water to cells to
maintain proper level.
Tools Needed:
rubber gloves
glasses
drybatt1 1/98 − 0886